OPERATORSETTINGS
Factory sengs
To set operator sengs hold the SETUPbuon 100x50
down and turn ON, the display will show WELTECH
SETUP when the buon is released DATASTORES
will be displayed, by pressing the INC or DEC arrows
the number of houses or pens data is to be stored
in can be set, 1x5000 to 100x50, when set press ENTER.
SELECTSTOREON
This funcon allows the user to select the house or
pen in which the bird weights are to be stored. If
turned off the weighings will be stored in numerical
order.
ENABLEBUTTONS ON
Allows full usage of the front panel
BLUETOOTHRATE 9600BAUD
Not an available opon.
PRINTERRATE 9600BAUD
This is the speed the data is sent to the printer and
can be changed using the INC or DEC buons. Baud
rate for serial port.
BLUETOOTHH/SHK OFF
Not an available opon.
PRINTERH/SHK OFF
This is not used with our printer.
PRINTERLINEFEED ON
Sends line feed to printer after a new line
PRINTERDELAY 0.1SECS
This is the delay time from pressing the print
data button to the actual print function.
WEIGHTRANGE ChickenorTurkey
To be set to the weight capacity of the BW‐2050
10kgs for chickens, 50kgs for Turkeys.
WEIGHTUNITS KGS
This option allows the operator to select the
measurement of weight to be used kgs, grms, lbs.
BACKLIGHTTIMED
This option allows for the display back light to
be turned off, on or on for a 30 second period.
GRADELAMPS OFF
When the weigher has grading lights fitted
this is ON when using the grading lights.
DIGITCLAMP1
Displays Filter (if weight filter is enabled )
4
5