PROBLEM CAUSE SOLUTION
Circuit breaker keeps tripping.
Wrong extension cord size used.
Use properly-sized extension cord (see
chart on p. 7).
Dull cutting inserts.
Check cutting inserts. Rotate or re-
place as necessary.
Excessive depth of cut. Reduce depth of cut.
Internal motor problem.
Contact customer service at 1-800-
232-1195 for assistance.
Drive rollers do not work,
or excessively loud grinding
noise.
Broken gearbox, drive chain, or
sprocket.
Contact customer service at 1-800-
232-1195 for assistance.
Marks on the workpiece.
Dull cutting inserts.
Check cutting inserts. Rotate or re-
place as necessary.
Excessive depth of cut. Reduce depth of cut.
Workpiece being fed against grain. Reverse workpiece.
Table or feed rollers are dirty. Clean table and/or feed rollers.
Dust or debris between cutting inserts
and cutterhead.
Clean cutting inserts and cutterhead.
Snipe.
Dull cutting inserts.
Check cutting inserts. Rotate or re-
place as necessary.
Improper support being used.
Support workpiece properly (especially
long workpieces). See recommenda-
tions on p. 6.
Infeed or outfeed table improperly
adjusted.
Adjust infeed and outfeed tables as
described on p. 17.
Table or feed rollers are dirty. Clean table and/or feed rollers.
TROUBLESHOOTING GUIDE
WARNING! Stop using the tool immediately if any of the following problems occur. Repairs and replace-
ments should only be performed by an authorized technician. For any questions, please contact our customer
service at 1-(800) 232-1195, M-F 8-5 CST or email us at techsupport@wenproducts.com.