M/S MANUAL BACK-UP ACCESSORY
ILLUSTRATION-069
WESTCO MANUAL BACK-UP ASSEMBLY
1. Install manual back-up hanger assembly on tong, insuring that leveling adjustment bolt is to the
rear of the tong.
2. Install back-up tool in hanger assembly, place pin and safety clip in lever to secure assembly.
3. To set manual back up for breakout, the lug jaw assembly (Ref. 422) must be positioned on right
hand side of back up.
4. To operate back up, position the tong on pipe so that the lug jaw system is gripping. Using both
hands, install lever latch in lug jaw assembly in a position to grip tubing coupling. Firmly hold
lever latch with one hand, using opposite hand to operate tong throttle. Break out joint, push on
lever latch to release.
5. For make-up of tubing, remove lever latch assembly from hanger assembly. Reposition and
install so that lug jaw is on left hand side. Position the tong on tubing and grip pipe with jaw
system. Install lever latch in lug jaw so that back up will grip on upset below coupling. This will
ensure that the coupling is made-up to proper torque.
a. To prevent injury, always grip lever latch loosely with palm of hand. Lever latch and lug jaw
may become separated if not fully engaged on teeth of lug jaw when torque is applied to
tubing.
b. Westco recommends that the back-up tong be used only when necessary. This will minimize
wear and reduce labor.
BACK-UP USAGE
The back up should be used during the following conditions:
1. When pulling tubing out of the well and the coupling unscrews from pin on tubing in the well.
2. When weight of pipe becomes light enough to allow pipe to rotate in slips.
3. When running tubing in well until load is significant to prevent tubing from rotating in the slips.
To prevent rotating, secure tubing spider to wellhead.
NOTE: When running tubing in the hole, back up must be used: 1. On the upset below the tubing
coupling to insure proper make-up of coupling. 2. To prevent string from turning in the slips. 3. To
ensure the make-up of both threaded connections.