Generic I/O
The generic I/O gives the following functionality:
1. Establishing a data connection to a predefined target number
When the input is pulsed, the modem establishes a data connection to the stored  
predefined number. After a time (specified in the modem) without data exchange,  
the connection is released by an inactivity timer.
2. Sending an SMS Message to a predefined targetnumber
When the input is pulsed, the modem will send an SMS to a predefined number.  
The SMS Messages can handle at least 160 characters. TAP and UCP protocols are  
supported.
3. Sending a Text Message to a predefined targetnumber
When the input is triggered, the modem will establish a connection to the stored 
modem number and transfer a predefined text message. This is not an SMS message.
4. Using the remote digital output
When the input is triggered, the modem will establish a connection to the stored  
number of a remote TD-36 and send out a command, that pulses the remote output 
according to a predefined sequence. 
5. Executing an AT-Command string 
Pre-programmed AT command strings stored in the modem can be executed.  
These can (for example) be used for switching DTE communication parameters for 
online and offline modes by using two entries.
6. Transparent I/O 
When the input is triggered, the modem will establish a connection to the stored  
number of a remote TD-36 and send out a command, and after a connection is  
established, the I/O is bi-directional.