16
Operation
WARNING
THE OPERATOR SHOULD NEVER PUT HIS OR HER
HANDS IN THE CYLINDERS!
9) Start the engine and turn the pump on.
Cycle a few times to make sure there is no material
left in the cylinders.
10) With a bent rod or broom handle remove
any build up of material.
11) Clean the clean-out door opening. The
clean door and opening must have a good seal.
(Not leak water) If the seal is not good the pump will
suck air through it instead of concrete- resulting in
partially filled material cylinders.
12) Lubricate the pump module at these five
locations:
a) Flange Bearing.
b) S-Tube shift Cylinder Base.
c) S-Tube shift Cylinder Yoke.
d) Remixer Housing.
e) Outlet Flange.
It is important to lubricate the pump module after
clean up. This pushes out water, cement, and other
contaminants before they can harden. Failure to
lubricate the pump module properly even once
will cause premature wear and or damage to the
machine resulting in expensive downtime.