22
Service Information
• Recommended engine oil: Shell Rotella T 15W-40 or
comparable. Capacity: 4 gallons.
• Recommended hydraulic fluid: ISO-68, AW-68 (20W),
Qualified against Denison HF-0. Meeting requirements
of Vickers M-2950-S and 1-286-S specifications.
Maintenance Schedule
• Grease machine twice daily at all grease fittings
especially after clean up.
• Replace engine oil, oil filter, and fuel filter every 500
hrs.
• Drain water separator monthly and replace element
every 1000 hours or every 1 year.
• Inspect and/or replace engine air filter every 250 hrs.
• Replace Cups (85704) and Cup adapter O-Rings
(85707) when water-box is full of slurry or every 250
hrs. Fill water-box halfway with used or new hydraulic
fluid.
• Replace Wear-plate (85131) & Wear-ring (85334) every
500 hrs or when build-up occurs.
• Change hydraulic fluid and Filter and inspect tank
plumbing for loose fittings and/or breaks at the 1st 300
hrs, then every 1 year or every 1000 hrs.
• Inspect frame for cracks every 500 hrs.
• Inspect surge brake assembly for proper operation
every 500 hrs.
• Inspect entire machine every 250 hours for loose parts,
fittings, fasteners, etc.
X500
CUMMINS 3.8
STAGE V
CUMMINS 6.7
TIER 3 MODELS
CUMMINS 6.7
TIER 4-I MODELS
CUMMINS 6.7
TIER 4-F MODELS
X600
CUMMINS 6.7
STAGE V
OIL FILTER
52131 82085
FUEL FILTER
52132 82086 82086-ST5
PRIMARY AIR FILTER
52133 82020.02
SECONDARY AIR FILTER
52134 82020.03
FUEL/WATER SEPARATOR
82020.48 82087 82020.40 82020.48 82020.49
Maintenance