EasyManua.ls Logo

Westfield MKX130-94 - User Manual

Default Icon
124 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Part Number: 30797 R5
Revised: 1/6/2017
Read this manual before using product. Failure
to follow instructions and safety precautions can
result in serious injury, death, or property
damage. Keep manual for future reference.
GRAIN AUGERS
MKX130-84/94/114
ASSEMBLY & OPERATION
ORIGINAL INSTRUCTIONS

Table of Contents

Questions and Answers

  • C
    Christine BrownAug 5, 2025
    Why is my Westfield MKX130-94 Farm Equipment auger not turning?
    • D
      Denise ThomasAug 5, 2025
      The auger might not be turning due to several reasons: it could be plugged or obstructed, in which case you should identify and remove the obstruction. Alternatively, a bearing or the gearbox may have seized, requiring you to identify and replace the bearing, or fix/replace the gearbox. A chain could be broken, requiring repair or replacement. Another possibility is that the gearbox coupler bolt or the PTO shear bolt is broken or missing, and you'll need to replace the bolt.
  • C
    ccrawfordAug 9, 2025
    What to do if my Westfield Farm Equipment auger is noisy?
    • B
      Brian NelsonAug 9, 2025
      If your Westfield Farm Equipment auger is making unusual noise, it could be due to several factors. There might be an obstruction in the auger, which requires identification and removal. Check if the flighting shaft bolts are loose or damaged, and tighten or replace them as needed. The auger shaft could be bent or the flighting damaged, necessitating repair or replacement of the shaft or flighting. A worn bearing or low gear oil level in the gearbox can also cause noise; repair or replace the bearing, or inspect the gearbox for damage and add oil if no damage is found. Lastly, a misaligned tube could be the culprit, requiring adjustment of the truss cables.
  • J
    James CastilloAug 13, 2025
    Why Westfield MKX130-94 auger will not raise or lower?
    • C
      Christopher BakerAug 13, 2025
      If your Westfield Farm Equipment auger isn't raising or lowering, check for a closed hydraulic valve and open it. Inadequate hydraulic pressure could be the issue; adjust the pressure or use an alternate hydraulic supply. A damaged cylinder, missing or broken cylinder pin, or a hydraulic system leak could also be the cause, requiring you to fix or replace the cylinder, replace the cylinder pin, or identify and repair the leak. Finally, an obstruction to the auger's movement could be the problem; identify and clear any obstructions.
  • D
    Diane ClarkAug 17, 2025
    What to do if Westfield MKX130-94 auger will not stay in elevated position?
    • K
      Kristi DaviesAug 17, 2025
      If your Westfield Farm Equipment auger isn't staying in the elevated position, it could be due to a leak in the auger's hydraulic cylinder or fittings. Identify and repair the leak. Another potential cause is a leak in the tractor hydraulics; close the hydraulic valve to isolate the cylinder from the tractor hydraulics.
  • M
    Michael AlexanderAug 22, 2025
    Why is the material augering rate low on my Westfield MKX130-94 Farm Equipment?
    • S
      Steven MarshallAug 22, 2025
      A low material augering rate in your Westfield Farm Equipment can stem from several issues. The tractor PTO speed might be too slow, so increase the engine rpm. Check for inadequate material flow from the truck or hopper and increase the flow. A restricted flow into the auger hopper due to obstructions on the grating can also cause this; clear any obstructions. Note that unloading rates are for dry grain, so if the material is too wet or heavy, this could be the reason. Lastly, worn flighting can reduce the rate; repair or replace as required.
  • K
    Kathryn RodriguezAug 27, 2025
    What to do if upper auger sections will not turn in Westfield MKX130-94?
    • L
      linda66Aug 27, 2025
      If the upper auger sections of your Westfield Farm Equipment are not turning, the coupler bolt below the non-rotating section might be broken or missing. Replace the bolt.
  • Y
    ynelsonAug 30, 2025
    Why is the tube misaligned on my Westfield MKX130-94 Farm Equipment?
    • M
      michaeltranAug 30, 2025
      If the tube on your Westfield Farm Equipment is misaligned, it might be due to loose truss cables. You should tighten the cables as required.

Summary

1. Introduction

1.1.1. Auger Power Source

Explains standard and optional PTO drive systems for powering the auger.

2. Safety

2.1. General Safety Information

Defines safety alert symbols, signal words, and general safety principles.

2.2. Assembly Safety

Provides essential safety guidelines and precautions to be followed during equipment assembly.

2.3. Operation Safety

Outlines critical safety procedures for operating the auger to prevent injury or damage.

2.4. PTO Safety

Details safety precautions related to the PTO driveline to prevent accidents.

2.5. Hydraulic Safety

Covers safety measures for the hydraulic system, including leak prevention and safe handling.

2.6. Transport & Placement Safety

Provides safety guidelines for transporting and positioning the auger to prevent accidents.

2.7. Maintenance Safety

Details safety procedures to follow when performing maintenance or servicing the auger.

3. Assembly

3.2. Assemble the Auger Tube

Covers the process of assembling the main auger tube sections, including identification and arrangement.

3.7. Connect the Auger Tube to the Frame

Instructions for connecting the assembled auger tube to the auger frame.

3.10. Connect the PTO Driveline

Instructions for securely connecting the PTO driveline to the auger for power transmission.

3.15. Auger-to-Tractor Hookup

Explains proper procedures and measurements for hitching the auger to a tractor.

4. Transport

4.1. Transport Procedure

Provides a step-by-step guide for safely preparing and transporting the auger.

5. Placement

5.1. Placement Procedure

Details the steps for safely positioning the auger at the operating location.

6. Operation

6.2. Pre-Operation

Lists essential checks and procedures to perform before operating the auger.

6.2.1. Checklist

A comprehensive checklist of all items to inspect and verify before starting the auger.

6.2.2. PTO Drive

Details on ensuring the PTO drive system is correctly set up and safe for operation.

6.2.3. Hydraulics

Pre-operation checks for the hydraulic system, including connections and fluid.

6.3. Operating Procedures

Step-by-step instructions for the normal and emergency operation of the auger.

6.3.1. Initial Start-Up

Guidance for the first-time startup of the auger, including break-in procedures.

6.3.2. Normal Start

Procedures for safely starting the auger for regular grain transfer operations.

6.3.4. Emergency Stop; Full-Tube Restart

Instructions for emergency shutdown and restarting the auger if it becomes filled with material.

7. Maintenance and Storage

7.3. Maintenance Procedures

Step-by-step instructions for performing various maintenance tasks on the auger.

Westfield MKX130-94 Specifications

General IconGeneral
BrandWestfield
ModelMKX130-94
CategoryFarm Equipment
LanguageEnglish

Related product manuals