GENERAL INFORMATION
WF-8930/50 Series Distribution Center Safety Features
Reverse Battery Protection
e WF-8930/50 Series Distribution Centers DO NOT have a converter installed within the
enclosure. Power is supplied to the WF-8930/50 Series Distribution Centers from an external
converter/charger, WF-9800 Series Converter/Charger for example, located elsewhere in the
RV. Reverse Battery Protection will be provided by that unit. Consult that converter/charger’s
manual for location and replacement instructions.
Blown Fuse Indicators on DC Fuse Board
e DC Fuse Board has individual blown fuse indicators as standard equipment. e
WF-8930/50 Series Distribution Centers have 15 DC circuits. Each of the circuits contain a Red
LED to indicate a blown fuse. If one of the circuits draws more current than the rating of the
fuse, the fuse will blow. When this occurs, the Red LED for that circuit will illuminate. NOTE:
e fuse board employs surface mount LEDs which are barely visible to the naked eye. Replace
the blown fuse with a known good fuse of the same rating. NOTE: If the replacement fuse blows
again, check that circuit for a short or overload condition.