If the above checks have been made but the problem cannot be resolved, contact the Arterra
Distribution Power PROs at 1 (877) 294-8997. Before placing the call, please have available
the WF-8930/50 Series Distribution Center model number from the front panel label and
the 14-digit serial number from the bar code tag located inside the enclosure. Remove the
door assembly to gain access to the inside to locate this serial tag.
Should it be determined that the fuse board of the WF-8930/50 Series Distribution Center is
defective, and the unit is under still warranty, the fuse board ONLY will need to be returned.
DO NOT return the complete WF-8930/50 Series Distribution Center.
e DC wires protruding from the back of the WF-8930/50 Series Distribution Center have
been connected to the DC circuits in your RV by the RV manufacturer. When preparing the
fuse board for return, label and disconnect each wire as it is removed from the fuse board
lug. Follow the packaging instructions in your warranty claim packet.
GENERAL COMPLIANCE INFORMATION
Agency Listings
UL
e WF-8930/50 Series Distribution Centers are UL-Listed, and cUL-Listed (Canadian).
TROUBLESHOOTING INSTRUCTIONS
7
INSTALLATION INSTRUCTIONS
Installing the WF-8930/50 Series Distribution Center
Mounting the Enclosure
e WF-8930/50 Series Distribution Center enclosure should be mounted in an accessible area
such as a wall or in the side of a cabinet near the Shore power entrance and battery (batteries).
Select a mounting location that is appropriate to prevent excessive heat, water, moisture, dust
and dirt entering the unit once installed.
Cut an opening 1/8” wider than the enclosure to allow the distribution center to slide in easily.
e rough opening is 12 3/16” W x 8 3/16” H. e enclosure is 3” deep. Be sure to allow enough
space behind the unit for wiring. Aer wiring is completed, the enclosure fastens to the wall or
cabinet using 4 wood screws (not supplied).