EasyManua.ls Logo

Whirlpool AMC 991 User Manual

Whirlpool AMC 991
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
29
INSTRUCTIONS FOR USE
SINGLE SPLIT AIR CONDITIONER WITH
GAS R410A / R410A INVERTER
PRECAUTIONS FOR USE
SPECIFICATIONS AND TECHNICAL DATA
(DEPENDING ON THE MODEL)
INSTRUCTIONS FOR USE
DESCRIPTION OF AIR CONDITIONER
COMPONENTS
HOW TO USE REMOTE CONTROL
CLEANING AND MAINTENANCE
TROUBLESHOOTING
INSTALLATION SERVICE - PRECAUTIONS
ON INSTALLATION
ELECTRICAL SAFETY REQUIREMENTS
INSTALLATION DIMENSION DRAWINGS
INSTALLING INDOOR UNIT
CHECKS AND TEST RUN AFTER INSTALLATION
ELECTRIC HEATING BELT
ELECTRICAL CONNECTION
Thank you for selecting a Whirlpool air conditioner. For best results, please keep this Manual properly for
future reference.
This appliance is marked according to the European directive 2002/96/EC on Waste Electrical and Electronic
Equipment (WEEE).
By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for
the environment and human health, which could otherwise be caused by inappropriate waste handling of this
product.
The symbol on the product, or on the documents accompanying the product, indicates that this
appliance may not be treated as household waste. Instead it shall be handed over to the applicable collection
point for the recycling of electrical and electronic equipment.
Disposal must be carried out in accordance with local environmental regulations for waste disposal.
For more detailed information about treatment, recovery and recycling of this product, please contact your
local city office, your household waste disposal service or the shop where you purchased the product.
32602005GB.fm Page 29 Thursday, December 14, 2006 11:24 AM
Question and Answer IconNeed help?

Do you have a question about the Whirlpool AMC 991 and is the answer not in the manual?

Whirlpool AMC 991 Specifications

General IconGeneral
TypeSplit Air Conditioner
Operating Voltage220-240V
Operating Frequency50 Hz
Cooling Capacity9000 BTU/hr
FeaturesAuto Restart, Sleep Mode

Summary

PRECAUTIONS FOR USE

SPECIFICATIONS AND TECHNICAL DATA (DEPENDING ON THE MODEL)

INSTRUCTIONS FOR USE

Cooling Mode Principle and Functions

Explains how the air conditioner cools indoor air by transferring heat outdoors.

Heating Mode Principle and Functions

Describes how the unit absorbs heat from outside air to warm indoor spaces.

Air Conditioner Failure Causes

Lists conditions that may cause the air conditioner to stop operating.

DESCRIPTION OF AIR CONDITIONER COMPONENTS

Indoor Unit Components

Details the parts of the indoor unit of the air conditioner.

Outdoor Unit Components

Details the parts of the outdoor unit of the air conditioner.

HOW TO USE REMOTE CONTROL

Operating Procedures

Covers general and optional steps for operating the unit.

Remote Control Key Functions

Explains the purpose and function of various keys, including mode, fan speed, timer, and special functions.

Battery Replacement and Emergency Operation

Instructions for replacing batteries and emergency operation.

CLEANING AND MAINTENANCE

Cleaning the Front Panel

Instructions for removing and cleaning the front panel of the indoor unit.

Cleaning the Air Filter

Steps for cleaning the air filter of the air conditioner.

Seasonal Use Checks and Maintenance

Covers pre-season checks and post-season maintenance tasks.

TROUBLESHOOTING

INSTALLATION SERVICE - PRECAUTIONS ON INSTALLATION

Indoor Unit Installation Position Selection

Guidelines for choosing the optimal location for the indoor unit.

Outdoor Unit Installation Position Selection

Guidelines for choosing the optimal location for the outdoor unit.

ELECTRICAL SAFETY REQUIREMENTS

Grounding Requirement

Details the essential grounding procedures for safe operation.

Other Electrical Requirements

Covers additional electrical safety guidelines and connections.

INSTALLATION DIMENSION DRAWINGS

INSTALLING INDOOR UNIT

Wall Mounting and Pipe Installation

Procedures for mounting the frame and installing wall pipes.

Drainage Pipe and Cable Connections

Instructions for installing the drainage pipe and connecting cables.

Installing the Unit and Connecting Pipes

Details hanging the indoor unit on the frame and connecting refrigerant pipes.

Vacuum-pumping and Leakage Inspection

Draining of Condensate Water of Outdoor Unit

CHECKS AND TEST RUN AFTER INSTALLATION

Post-Installation Checks

A checklist of items to verify after the installation is complete.

Test Run Procedures

Steps to perform a test run to ensure proper operation.

Electric Heating Belt Functionality

Details the function and operation of the electric heating belt for specific models.

ELECTRICAL CONNECTION

Electrical Connection for Great Britain

Specific electrical connection and fuse replacement for UK plugs.

Electrical Connection for Republic of Ireland

Notes on electrical connection specific to Ireland.

Socket Outlet and Plug Guidelines

Guidance on plug suitability and professional replacement.

Related product manuals