DB200
WHIRLPOOL
DEHUMIDIFIER
೎҃঒
٩ᒅ፟
DB200
Cfgpsf!pqfsbujoh!uif!voju-!qmfbtf!sfbe!uijt!nbovbm!uipspvhimz-
boe!sfubjo!gps!gvuvsf!sfgfsfodf/
ፆү݈ĂኛͿ௟ዦ᝝ώᄲځĂ֭ኛԁܲхĂͽ౯ޢણ҂ϡĄ
PXOFS(T!JOTUSVDUJPOT!!!!
ֹϡᄲځ
Question and Answer IconNeed help?

Do you have a question about the Whirlpool DB200 and is the answer not in the manual?

Overview

The Whirlpool DB200 Dehumidifier is designed to efficiently remove moisture from the air, offering a range of features for optimal performance and user convenience.

Function Description

The dehumidifier offers four primary operating modes: Auto, Continuous, Quiet, and Dry.

  • ON/OFF: To power on the machine, simply press the ON/OFF button after connecting it to the power supply.
  • Mode Selection: The MODE button allows users to cycle through the available operating modes: Auto, Continuous, Quiet, and Dry.
  • Auto Mode: In Auto mode, the machine automatically maintains a room humidity level ranging from 40-60%. The auto indicator lights up when this mode is active.
  • Continuous Mode: This mode is ideal for environments requiring significant dehumidification. When the continuous indicator is lit, the machine operates continuously, suitable for super dry conditions.
  • Quiet Mode: When the quiet indicator is lit, the machine operates at a low fan speed to minimize noise. The fan speed cannot be manually adjusted in this mode.
  • Dry Mode: The dry indicator illuminates when this mode is active. The machine continuously dehumidifies to maintain a specific humidity range, preventing mold and mildew. Fan speed and humidity settings are not adjustable in Dry mode.
  • Humidity Setting: Users can set their desired humidity level by pressing the Humidity button. Holding the button allows for incremental adjustments of 10% within a range of 30-80%. The set humidity value is displayed for 5 seconds after adjustment.
  • Timer Setting: The Timer button allows for setting an ON or OFF timer. Each press increases the timer by 1 hour, with a range of 0-24 hours. Holding the button enables continuous adjustment. The timer setting is displayed for 5 seconds, and the timer indicator lights up.
  • Fan Setting: The Fan button controls the fan speed, offering High, Medium, and Low options. The corresponding indicator light shows the selected fan speed.
  • Filter Reset: When the filter cleaning indicator is lit, it's time to clean the filter. After cleaning, simultaneously press the Fan and Humidity buttons to reset the indicator.
  • Child Lock: To activate the child lock, press the MODE and TIMER buttons simultaneously for one second. "LC" will appear on the display, indicating that the buttons are locked. Pressing MODE and TIMER simultaneously again will unlock the function.

Important Technical Specifications

  • Model: DB200
  • Control: Microchip Control
  • Dehumidification Capacity:
    • 20 liters per day (30°C, 80%RH)
    • 12 liters per day (26.7°C, 60%RH)
  • Voltage: 220~240V, 50Hz
  • Operating Temperature: 5°C - 35°C
  • Dimensions (W x D x H): 34.5cm x 21.0cm x 57.5cm
  • Net Weight: 14kg
  • Additional Features: Automatic defrost and automatic stop when the bucket is full.

Usage Features

  • Air Purification: The unit includes an air purifying function with a removable and washable pre-filter.
  • High Efficiency: Offers powerful drying and dehumidifying capabilities.
  • Fan Speed Selection: Three fan speed options (High, Medium, Low) are available to suit different needs.
  • Humidity Display: The display window shows the actual room humidity status.
  • Portability: Compact design with a handle for easy lifting and a slim shape for convenient storage.
  • Positioning: For optimal performance and safety, the unit should be placed upright on a stable, flat surface. Maintain a minimum distance of 20cm from walls and furniture on all sides, and at least 50cm from the unit's air outlet when using the dry function.
  • Bucket Full Indicator: The "Water Full" indicator illuminates when the water bucket is full or improperly fitted, stopping the unit's operation.
  • Continuous Draining: The unit supports continuous draining via a drain outlet (14mm inner diameter hose, purchased separately). This feature requires turning off the unit and unplugging it before installation. The drain hose should not be higher than the drain outlet to ensure proper water flow.

Maintenance Features

  • Cleaning the Unit:
    1. Switch off and unplug the unit.
    2. Clean the air intake and outlet with a soft cloth to remove dust.
    3. Avoid using petrol or solvents for cleaning.
    4. Wipe the surface with a soft damp cloth using water or mild detergent.
    5. Dry the unit with a dry cloth.
    • Note: Never wash the unit directly with water to prevent internal damage.
  • Cleaning the Air Filter:
    1. Remove the panel: Press the buckles on both sides of the panel's lower end to open it by about 20 degrees. Then, press again to lift the panel upwards and remove it.
    2. Remove the air filter: Pull the upper tab of the air filter outwards to detach it.
    3. Clean the air filter: Use a vacuum cleaner to remove dust. If the filter is very dirty, wash it with warm water and a neutral detergent, then dry it thoroughly.
    4. Install the air filter: Insert the lower tab of the air filter back into the main unit, then press the air filter back until the upper tab clicks into place. Reattach the panel.
    • Recommendation: Check and clean the filter every two weeks to maintain efficiency.
  • Long-term Storage:
    1. Insert the power plug into the power cord hole and secure the power cord with a cable tie.
    2. Drain all water from the bucket and clean it with a soft cloth.
    3. Clean the air filter.
    4. Cover the unit to prevent dust accumulation and store it vertically in a cool, dry place.

System Description

  • Compressor: After connecting to power, allow 3 minutes for the compressor to restart if it was previously stopped.
  • Temperature Sensor: If the display shows "F2" during operation, it indicates a damaged temperature sensor. Only the ON/OFF button will be functional in this situation.
  • Water Full: If the water bucket is full or removed for over 3 minutes, the FULL indicator will light up, and an audible "beep" will sound. The machine will resume operation once the bucket is emptied and properly reinserted.
  • Auto Power Off: In Continuous mode, the machine automatically stops when the water bucket is full, removed, or incorrectly positioned.
  • Auto-defrost: The compressor automatically stops if the evaporator is covered with frost. The fan continues to run until defrosting is complete, after which the machine restarts automatically.
  • Memory Function: In case of power failure, all previous settings are memorized and restored upon power recovery.

Whirlpool DB200 Specifications

General IconGeneral
BrandWhirlpool
ModelDB200
CategoryDehumidifier
LanguageEnglish