Bio Energy Step 2
A-30% ECO Forced Air Description
Bio Energy Step 2
A-30% ECO Forced Air Description :
Cooling Fan delay: 15'
Eco mode always ON
NO pre-heating
Heaters period: 60s; Cavity fan period: 60s
First Phase: Ring and Grill are ON, duration 11', Cavity Fan is pulsed (30s OFF and 30s ON
without considering fan inertia)
Second Phase: Ring element is ON, duration about 60', Cavity Fan is pulsed (45/48s OFF
and 15/12s ON without considering fan inertia, depending on models)
Third Phase: Ring and Grill are ON, duration up to 720', Cavity Fan is pulsed (45/48s OFF
and 15/12s ON without considering fan inertia, depending on models)