Bio Energy Step 2
A-40% ECO Forced Air Description
Bio Energy Step 2
A-40% ECO Forced Air Description :
•Double ring element
•Double speed cavity fan motor
•Cooling Fan delay: 30`
•Eco mode always ON
•NO pre-heating
•Heaters period: 60s; Cavity fan period: 60s
•The cavity lamp is switched off after 1`
First Phase: Low Banana Ring is ON, duration 20', Cavity Fan is always ON (low speed)
°C, duration 8', cavity fan is
pulsed (low speed; 36s OFF and 24s ON without considering fan inertia)
Third Phase: Low Banana Ring element is ON, duration about 40', Cavity Fan is pulsed
(low speed; 36s OFF and 24s ON without considering fan inertia)
Fourth Phase: Low Banana Ring element is ON, duration up to 720', Cavity Fan is pulsed
(high speed; 36s OFF and 24s ON without considering fan inertia)
The Software of the Antares control board and the Navigator user interface has been
modified compared to A-30%.