This document describes the Whirlpool Ionizer SS226 Dehumidifier, also referred to as the Whirlpool Ionizer SS226 抽濕機. It serves as an owner's manual, providing instructions for safe use, operation, and maintenance.
Function Description
The Whirlpool SS226 is a multi-functional appliance designed for dehumidifying, drying, and air purifying. Its core function is to remove excess moisture from the air, making it suitable for various environments and purposes, including drying clothes. The unit also incorporates an air purifying system with multiple filters and an ionizer to improve air quality.
Key functional aspects include:
- Dehumidifying Mode: Reduces room humidity, with adjustable humidity settings (40-50%, 50-60%, 60-70%) or continuous operation. It features a low fan speed during this mode, and the ionizer is active.
- Drying Mode (Laundry): Specifically designed for drying clothes quickly and efficiently, utilizing a high fan speed. The humidity cannot be set in this mode.
- Air Cleaning Mode: Operates solely as an air purifier with a low fan speed and active ionizer, without dehumidification.
- Internal Drying Function: After dehumidifying, a one-hour internal drying mode can be activated to dry the cooler inside the machine, inhibiting mildew growth.
- Automatic Defrost: Ensures efficient dehumidifying even at lower temperatures (above 5°C) by automatically defrosting the unit.
- Humidity Status Display: Provides a visual indication of room humidity using three corresponding colors: orange (above 60%), yellow (50-60%), and green (below 50%).
- Timer Function: Allows users to set an auto-off timer for 2, 4, 8, or 12 hours, or to run continuously.
- Louver Setting: Features a vertical louver with three range selections (75° upwards, 75° forwards, and 150° wide range) to direct the dried air to desired portions. The louver automatically closes when the unit is unplugged or shut down and turns upwards with horizontal blades turning forward upon re-plugging.
Important Technical Specifications
- Model: SS226
- Control: Microchip Control
- Dehumidification Capacity:
- 20 liters per day (at 30°C, 80%RH)
- 12.1 liters per day (at 26.7°C, 60%RH)
- Voltage: 220-240Vac, 50Hz
- Ambient Temperatures: 5°C to 32°C
- Dimensions: 172mm (W) x 387mm (D) x 574mm (H)
- Net Weight: 11.8kg
- Safety Features: Auto defrost, auto stop when the bucket is full.
- Power Cord: Requires connection to an earthed 3-pin socket.
Usage Features
- Portability: Compact design with a retractable handle for easy lifting and movement. Equipped with castors for mobility, though it's advised to lift the unit on uneven surfaces or thick-pile carpets to prevent damage.
- Placement: Should be placed upright on a stable, flat surface, with specific clearances from walls (at least 5cm), furniture (at least 10cm), and laundry (at least 50cm). A gap of 5-10cm around the unit is recommended for proper ventilation.
- Bucket Operation: The unit stops and illuminates a 'Full' indicator when the water bucket is full or improperly fitted. The bucket must be emptied and correctly re-inserted for continued operation. It's important not to remove the bucket too soon after operation to avoid dripping, and not to damage the float inside.
- Continuous Draining: An option for continuous water drainage is available using a pipe with an inner diameter of 11.5-12mm. The pipe should be connected to the outlet nozzle at the back and positioned below the unit without kinks.
- Initial Setup: Before first use, the 3-in-1 filter (catechin, deodor, charcoal) must be unpacked and installed into the filter frame at the back of the unit. The slide cover of the louver must be opened before operating.
- Memory Function: The unit remembers previous operation settings (louver, timer, humidity, and function) after a power break, resuming them upon the next boot.
- Storage: For long-term storage, it's recommended to run the internal drying function or air cleaning for at least an hour, then switch off, unplug, clean and dry the bucket, and close the slide cover or cover the unit to prevent dust accumulation. Store vertically in a cool, dry place away from direct sunlight.
Maintenance Features
- Filter System:
- Nano-silver pre-filter: This filter can be washed and gently wiped clean. It should be checked and cleaned every two weeks to prevent dust accumulation, which can compromise airflow and unit performance.
- 3-in-1 filter (catechin, deodor, charcoal): This filter is not washable and should be replaced every 3 to 6 months. New filters can be obtained from the dealer.
- General Cleaning:
- The unit should be switched off and unplugged before cleaning.
- Air intake and outlet should be cleaned with a soft cloth to remove accumulated dust.
- The surface can be cleaned with a soft damp cloth using only water or mild detergent, then wiped dry with a dry cloth.
- Important: Do not use petrol or solvents for cleaning, and never wash the unit with water directly.
- Regular Inspection: For units used continuously or for long periods, regular inspection is advised to prevent overheating or short circuits. If the unit operates in the same position for some time, check for dirt underneath and around it, and periodically move the unit to clean the floor.
Safety Precautions
The manual emphasizes several safety precautions, categorized as "Actions to be strictly avoided" and "Actions you must take." These include:
- Using only the specified voltage (220-240Vac, 50Hz).
- Not modifying or damaging the mains cable/plug.
- Not inserting fingers or foreign objects into air intake/outlet.
- Not placing aerosols, hazardous, or inflammable materials nearby.
- Not splashing or washing the unit.
- Not placing the unit near a heat source.
- Not modifying, disassembling, or repairing the unit by unqualified persons.
- Unplugging the unit and contacting service if anything abnormal (e.g., burning smell) is noticed.
- Ensuring the plug is clean and dust-free before plugging in.
- Replacing a damaged supply cord only by the manufacturer, service agent, or qualified persons.
- Operating the unit only on level, stable surfaces.
- Ensuring the louver slide cover is open before operating.
- Not using a drain hose in temperatures below 0°C.
- Ensuring the water tank is empty before moving the unit.
- Allowing a 5-10cm gap around the unit for ventilation.
- Not moving the unit on its castors on uneven surfaces.
- Not toppling, dropping, or placing the unit on its side.
- Not operating the unit in confined spaces like cupboards.
- Not placing water containers on the unit.
- Using the unit for indoor purposes only, avoiding direct sunlight or unsheltered locations.
- Not using the unit to control ambient temperature for storage of artworks or books.
- Not drinking the drain water.
- Not standing or leaning on the unit.
- Not placing the unit near a burner.
- Not obstructing air intake or outlet.
- Not using the unit above floor level (e.g., on a table).
- In case of compressor overheating and automatic cut-out, unplug the appliance, rectify the problem, wait 45 minutes, and restart.
- Contacting the manufacturer if indicator lights flash on the panel preventing operation, indicating a fault.