WWA-780
e. Spin Drying
Yes
No
TROUBLE INSPECTION CAUSES REMEDY INSPECTION
Note: In draining, the water lever sensor can
not reset in 8minutes.
The number window LED display
abnormal code: and begin blinking
on and off at the same time and the
electric buzzer sounds to indicate a
problem.
Note: In draining, the water level sensor can
not reset in 10 minutes.
The number window LED display
abnormal code: and begin blinking
on and off at the same time and the
electric buzzer sounds to indicate a
problem.
Spin drying cycle
does not work.
INSPECTION
Does safety
device work?
Machine inclines. Replace with level.
The V-belt is slipping.
The V-belt is snapped.
Small pulley mounting
screw is loosed.
Motor is disconnected or
burnt.
Capacitor is broken or
disconnected.
Bearing ass
’
y is defective.
Torque motor is defective.
Brake lever is defective.
Thermostat on motor is
opened.
Poor contact of
connectors
Control circuit board is
Note:
1.
The safety switch works 3 times
continuously
or works 1 time in the
single program of spin-dry
.
The
number window LED display abnormal
code: and begin blinking on and off
at the same time and the electric buzzer
sounds to indicate a problem.
2. Do not disconnect the wire from the
capacitor, because this wire acts as
de-pressing noise from outside to the
micro-computer.
Drain takes time too
long.
Valve bellows is deformed.
Drain hose ass
’
y is
deformed.
Hose is connected in the
wrong way.
Hose is too long or position of
hose is too high.
Replace.
Repair or replace.
Repair.
Repair.
• If the Drain Hose is too long or high, it may
make draining impossible.
• The extend Drain Hose to a maximum long of
3 meters and maximum high of 10
centimeters.