www.whisperkool.com | Page 9
Ceiling Mount
Model
8000 Evaporator
(Fan Coil Unit)
8000 Condenser
(Air-Cooled Condensing Unit)
Cellar Size Approx. 2000 cu. ft. when cellar is fully insulated and sealed with a proper vapor barrier*
BTU/h w/85°F air entering
condenser coil
5254
Dimensions 35.75”L x 14.5”W x 12.75”H 16.08” L x 16.23” W x 12.61” H
Refrigerant R-134a
HP 2.06
Voltage Rating 115V (15-amp dedicated circuit required) 115V (15-amp dedicated circuit required)
Weight (lbs) 80 56
Amps Evaporator: 1 (running amps), compressor: LRA 50, RLA 9.3
Line Set Liquid line: ¼” liquid line; suction line ½” (less than 50 ft.), ⁄” (more than 50 ft.)
Drain Line ¼” ID clear plastic tubing (not provided)
Installation
Evaporator is installed in the cellar. Condensing unit can be installed up to 100 line feet from evapo-
rator unit.
Thermostat Aftermarket (24V thermostat not included)
Temp. Delta
Can maintain a 55°F cellar temperature with up to 110°F condenser air intake temperature
Warranty Two-year limited warranty (parts and labor)
CEILING MOUNT 8000 SPECIFICATIONS
* Sizing the Unit to the Room
The specication chart will provide information on the unit's cooling capacity. There are circumstances in which a cellar design may
require a larger unit due to preexisting design restrictions. Certain building materials such as glass, stone, or concrete may seem
adequate but do not oer the insulation capacity required to maintain the optimum temperature for storing wine. We recommend
purchasing a unit with a larger capacity to compensate for these design limitations. Undersized cooling units can lead to premature
failure and/or prevent the system from reaching the desired set temperature. As a result, they are not covered under warranty.