Page 4 | 1-800-343-9463
WCM 021219
BEFORE YOU START
1-800-343-9463
1. Inspect all components prior to installation. If damage is found, please contact your distributor or WhisperKOOL Customer
Service at 1-800-343-9463.
2. The evaporator unit requires a dedicated 115V, 15-amp circuit. The 4000 condenser requires a dedicated 115V, 15-amp
circuit. The 8000 condenser requires a dedicated 115V, 20-amp circuit. Use a surge protector with the unit. Do not use a
GFI (ground fault interrupter) line.
3. No communication cable is required between the evaporator and condensing unit.
4. A standard 18-5 thermostat wire must be run from the evaporator unit to the thermostat.
5. You are REQUIRED to install a drain line to remove condensation from the evaporator unit.
6. The warranty is not active until a warranty checklist has been received, reviewed, and approved.
7. The system is intended for use in properly designed and constructed wine cellars. Hire a professional wine storage
consultant with a valid contractor’s license to build your wine cellar.
8. WhisperKOOL requires that all split systems be installed by a certified HVAC-R technician only. NATE or equivalent is
recommended.
If you encounter a problem with your WhisperKOOL system, please refer to the Troubleshooting Guide. If you have any further
questions or concerns, or need assistance, please contact WhisperKOOLs Customer Service at 1-800-343-9463. Please be sure all
testing has been completed prior to contacting Customer Service. Please have your results ready for your representative.