Blue Residential Thermostat
with Automatic Heat/Cool
Changeover Option
Model Programming Choices
1F97-0671
7 Day 5/1/1 Day Non-Programmable
www.white-rodgers.com
PART NO. 37-6975A
0832
For Single Stage Applications
Installation and Operating Instructions for Model:
APPLICATIONS
THERMOSTAT APPLICATION GUIDE
1F97-0671 Residential Thermostat
SPECIFICATIONS
To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.
CAUTION
!
Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
CAREFULLY BEFORE INSTALLING OR OPERATING THIS
CONTROL COULD CAUSE PERSONAL INJURY AND/OR
PROPERTY DAMAGE.
Description
Heat Pump (No Aux. or Emergency Heat) Yes
Heat Only Systems Yes
Millivolt Heat Only Systems – Floor or Wall Furnaces Yes
Cool Only Systems Yes
Gas or Oil Heat Yes
Electric Furnace Yes
Hydronic (Hot Water) Zone Heat – 2 Wires Yes
Hydronic (Hot Water) Zone Heat – 3 Wires Yes
Wired Remote Temperature Sensor (Indoor or Outdoor) Yes
ATTENTION: MERCURY NOTICE
This product does not contain mercury. However, this prod-
uct may replace a product that contains mercury.
Mercury and products containing mercury must not be
discarded in household trash. Do not touch any spilled
mercury. Wearing non-absorbent gloves, clean up any
spilled mercury and place in a sealed container. For proper
disposal of a product containing mercury or a sealed
container of spilled mercury, place it in a suitable shipping
container. Refer to www.white-rodgers.com for location to
send product containing mercury.
Index Page
Installation 2
Wiring Connections 3
Wiring Diagrams 3
Thermostat Quick Reference 4
Installer Confi guration Menu 5
Operating Your Thermostat 8
Programming 9
Troubleshooting 12
Electrical Rating:
Battery Power . . . . . . . . . . . . . . . . . . . . . . . . . . mV to 30 VAC, NEC Class II, 50/60 Hz or DC
Input-Hardwire . . . . . . . . . . . . . . . . . . . . . . . . . 20 to 30 VAC
Terminal Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5A per terminal, 2.5A maximum all terminals combined
Setpoint Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 to 99°F (7 to 32°C)
Differential (Single Stage) . . . . . . . . . . . . . . . . . . . . Heat 0.6°F; Cool 1.2°F
Operating Ambient. . . . . . . . . . . . . . . . . . . . . . . . . . 32°F to +105°F (0 to +41°C)
Operating Humidity . . . . . . . . . . . . . . . . . . . . . . . . . 90% non-condensing max.
Shipping Temperature Range . . . . . . . . . . . . . . . . . -40 to +150°F (-40 to +65°C)
Dimensions Thermostat. . . . . . . . . . . . . . . . . . . . . . 4.2"H x 6.4"W x 1.7"D

Questions and Answers:

White Rodgers 1F97-0671 Specifications

General IconGeneral
BrandWhite Rodgers
Model1F97-0671
Schedule7-day programmable
Voltage24 VAC
Weight0.5 lbs
DisplayDigital
Temperature Range45°F to 90°F (7°C to 32°C)
Power SourceBattery
Stages2 heating, 2 cooling

Summary

Blue Residential Thermostat

APPLICATIONS

Overview of system compatibility and applications for the thermostat.

SPECIFICATIONS

Detailed technical specifications of the thermostat's electrical and physical properties.

General Safety Warnings

Critical safety instructions regarding electrical shock and property damage.

INSTALLATION

Installing New Thermostat

Detailed instructions for mounting and connecting the new thermostat base.

WIRING CONNECTIONS

Wiring Diagrams

Visual guides for connecting the thermostat to various heating and cooling systems.

INSTALLER/CONFIGURATION MENU

INSTALLER/CONFIGURATION MENU (Continued)

OPERATING YOUR THERMOSTAT

Heating System Operation

Steps to test and operate the heating system correctly.

Cooling System Operation

Steps to test and operate the cooling system correctly.

Choose System Setting

Selecting between Heat, Cool, Off, or Auto changeover modes.

Manual Operation (Bypassing Program)

How to manually adjust temperature and use the HOLD feature.

PROGRAMMING

Energy Saving Factory Pre-Program

Details the thermostat's default heating and cooling schedule settings.

PROGRAMMING (Continued)

Enter the Heating Program

Step-by-step guide to programming heating times and temperatures.

Enter the Cooling Program

Step-by-step guide to programming cooling times and temperatures.

TROUBLESHOOTING

Reset Operation

Procedure for resetting the thermostat to factory settings.

No Heat/No Cool/No Fan (Common Problems)

Troubleshooting common issues with heating, cooling, or fan operation.

No Heat

Diagnosing and resolving problems when the heating system is not working.

No Cool

Diagnosing and resolving problems when the cooling system is not working.

Heat, Cool or Fan Runs Constantly

Troubleshooting continuous operation of heating, cooling, or fan systems.

Cycles Too Fast or Too Slow

Resolving problems with narrow or wide temperature swings.