OPERATION OF BLAST CHILLERS / CHILLER FREEZERS
The cabinet is delivered ready to run. Plug (or connect) to the mains and the cabinet is ready for use.
Initially the cabinet will be in standby mode, shown by 3 dashes (- - -) in both display windows. The cabinet
needs to have run at least half an hour before being used.
All Blast Chillers have 3 basic modes:
1. Normal storage . +1°C/34°F to +3°C/37°F
2. Blast Chill Hard -10°C/14°F
3. Blast Chill Soft +1°C/34°F
Combination Blast Chiller Freezers have 2 further modes:
4. Freezer storage -18°C (0°F) / -22°C (-8°F)
5. Blast Freeze -25°C (-13°F)
STORE MODE
During store mode (with no alarm condition or defrost cycle running) the left hand window will display the
previous blast cycle duration and the right hand window will display the store temperature. Some chillers have
more than 1 fan installed these may not all operate during the storage mode, giving a reduced air circulation
within the chiller.
The type of store mode is indicated under button
using the combination chiller freezer.
From store mode the following functions can be achieved:
1. Go into standby mode by pressing and holding
2. Initiate the setting of a blast chill or freeze cycle by pressing
3. Initiate a manual defrost by pressing and holding both
all enabled food probes and their respective temperatures can be displayed in a
scrolling process (each probe’s information is displayed for 4 seconds):
while in the scrolling mode will enable users to move through the data slowly.
is pressed at any time the cabinet returns to normal store
mode.
Function 5 can be initiated in any operating mode except standby.
BLAST CHILL OR FREEZE PROGRAMMING
Check that the chillers is operating at storage temperature. Load the products for chilling/freezing - refer to
the previous loading information. If using, place the food probe into the centre of the product to be chilled.
Then programme the cycle as follows:
1. By pressing button ‘1’ to select the desired type of blast - soft blast (4 blocks), hard blast (2 blocks) or
freeze (single block). (Freeze option on Blast Chiller Freezer models only)
2. By pressing button ‘2’ select timer for the desired duration either 90 or if blast freezing 240 minutes or
probe (temperature controlled cycle)
3. By pressing button ‘3’ start the blast chill or freeze cycle.
If you are not happy with your selection press the
✗✗
button to cancel your selections and the cabinet will revert
back to store mode. Pressing the
✗✗
button will stop the blast chiller in mid cycle and will keep the time
displayed following cancellation until a new blast cycle is programmed - this will be displayed in the left window.
During defrost or blast cycle it is not possible to enter the blast set mode
Press button to select the right storage temperature if
for 3 seconds.
for 3 seconds.and
4. Pressing
FP1 03
FP2
02
5. Further pressing
If no button is pressed for 10 seconds or if