When a Blast Cycle has been initiated - the following will be displayed:
Left window - time counting up Right window - clockwise rotating LEDS signifying a cycle in progress
The blast cycle is ended under normal operation by:
- Reaching the required temperature +3°C/37°F or -18°C (0°F).
- Reaching the end of the designated time (90 or 240 minutes).
- Manual cancellation of the cycle by pressing
and holding for 2 seconds.
- Putting the controller into standby mode by pressing
A blast cycle may also be terminated due to the following faults or failures:
- Over temperature fault
- HP/LP fault (if enabled)
- Air probe (T1) failure
- Food probe failure - terminates the blast cycle if all the food probes fail. If a 3 probe system is used,
and 1 probe fails, the cycle will continue until the last working probe reaches temperature.
- Mains failure longer than 3 minutes.
At the end of a cycle, an audible alarm will sound for 10 seconds with the left window displaying the time and
in the right window the LEDs will start flashing.
DEFROST
A defrost cycle is automatically instigated at the end of each blast chill cycle to clear any ice from the
evaporator ready for the next cycle. During storage mode a defrost will be performed automatically at the
factory preset interval of 6 hours. If a blast cycle is cancelled the machine will automatically initiate a defrost.
During a defrost the display windows will indicated the following:
Following a blast chill cycle
An alarm condition is present
A mains failure has taken place and no blast chill cycle has been initiated
since the mains failure
A manual defrost can initiated by pressing and holding both
and
During the defrost cycle all fans will stop running. When running the defrost cycle is finished the compressor will run
for approximately 60 seconds before the fans cut in. It is safe to leave products in the cabinet during the defrost
cycle - the air temperature rises slightly but will not affect the products stored.
After every defrost there is a short period - about 5 minutes during which a blast cycle cannot be programmed. This
short interval is to allow defrost water to drain away from the evaporator. At the end of each cycle, a defrost
will automatically clear any ice from the evaporator ready for the next cycle.
00
90
dF
AL
dF
- - -
dF
for 3 seconds.