6.2 Function
The DrainLift XS-F has a level switch, which switches on the pump according to the water
level. It is switched off automatically after a set time.
The motor winding is protected by an overload safety device which automatically switches
off the pump and switches it on again after it has cooled down.
An integrated, mains-dependent alarm signal (buzzer) signals any operating faults which
occur. An additional potential-free contact (5 A/250 V) on the board can be used to for-
ward the signal.
7 Installation and electrical connection
DANGER! Risk of fatal injury!
Incorrect installation and inexpert electrical connection can pose a risk of fatal injury.
The installation and electrical connection may only be carried out by qualified person-
nel in accordance with the applicable regulations!
Observe the regulations on the prevention of accidents!
7.1 Preparing for installation
The DrainLift XS-F is designed for front wall installation (Fig. 4). The unit is installed directly
beside the module for a wall-hung toilet.
The unit must be installed in a room protected from frost.
The installation surface must be horizontal and flat.
The lifting unit and its electrical connection (power plug) must remain accessible for main-
tenance after it is installed.
Fig. 3: Connections
1 Pressure pipe
2 Ventilation pipe
3 Inlet for wall hung toilet, HT pipe DN 100
4 Inlet pipe for shower/bidet
5 Inlet pipe for washbasin
Dimensions
4
5
3
12
Ø110
Ø50
Ø50 75
168
73
515
Ø50
Ø50
37
37
37 37
35
180
271
410