6 Installation and operating instructions • Wilo-Padus MINI3 • Ed.01/2022-06
1.12 Clean and disinfect
Wear protective equipment!
The protective equipment prevents contact
with germs that are hazardous to health and
the disinfectant.
If a disinfectant is used, follow the manufac-
turer's instructions!
Wear protective equipment according to
the manufacturer's instructions! If in doubt,
ask your specialist dealer.
Inform all persons about the disinfectant
and how to use it correctly!
1.13 Maintenance tasks
Wear protective equipment!
Carry out maintenance work in a clean, dry
and well-lit place.
Only original parts of the manufacturer may
be used. The use of any non-original parts re-
leases the manufacturer from any liability.
Collect any leakage of fluid and operating
fluid immediately.
1.14 Operating fluid
The oil is located in the sealing chamber. It
serves to lubricate the seal on the motor and
pump side.
Absorb leakages immediately.
If major leakages occur, contact customer
service.
If the seal is defective, the oil enters the
pumped fluid and the sewer.
Collect waste oil by type (unmixed) and dis-
pose of it in accordance with regulations at a
certified collection point.
Skin contact: Rinse skin areas thoroughly
with soap and water. If skin irritation occurs,
consult a doctor.
Contact with eyes: Remove the contact
lenses. Rinse eye thoroughly with water. If
eye irritation occurs, consult a doctor.
Ingestion: Consult a doctor immediately! Do
not induce vomiting!
2 Product description and function
2.1 Description
Submersible pump for stationary and portable wet well installation
in intermittent operation.
Padus MINI3-V Padus MINI3-M
1
2
3
3
4
5
5
6 6
Fig.1: Overview
1 Handle
2 Motor housing
3 Discharge connection
4 Pump housing
5 Float switch
6 Connection cable
Padus MINI3-V...-P
Drainage pump with vortex impeller and vertical threaded connec-
tion. Hydraulics housing and impeller made of plastic. Surface-
cooled 1~ motor with integrated operating capacitor and self-
switching thermal motor monitoring. Stainless steel motor hous-
ing. Oil-filled sealing chamber with double sealing: a rotary shaft
seal is installed on the motor side, a mechanical seal on the pump
side. Detachable connection cable with fitted plug (CEE7/7).
Padus MINI3-V...-A
Drainage pump with vortex impeller and vertical threaded connec-
tion. Hydraulics housing and impeller made of plastic. Surface-
cooled 1~ motor with integrated operating capacitor and self-
switching thermal motor monitoring. Stainless steel motor hous-
ing. Oil-filled sealing chamber with double sealing: a rotary shaft
seal is installed on the motor side, a mechanical seal on the pump
side. Detachable connection cable with float switch and fitted plug
(CEE7/7).
Padus MINI3-V...-O
Drainage pump with vortex impeller and vertical threaded connec-
tion. Hydraulics housing and impeller made of plastic. Surface-
cooled 3~ motor with self-switching thermal motor monitoring.
Stainless steel motor housing. Oil-filled sealing chamber with
double sealing: a rotary shaft seal is installed on the motor side, a
mechanical seal on the pump side. Detachable connection cable
with bare cable end, for fixed connection to on-site controls. NO-
TICE!Pump without float switch and plug!
Padus MINI3-M...-P
Drainage pump with semi-open multi-channel impeller and ver-
tical threaded connection. Hydraulics housing and impeller made of
plastic. Surface-cooled 1~ motor with integrated operating capa-

Related product manuals