en Product description
14 WILO SE 2017-12
PRO C08...
DN80, PN10
PRO V10...
DN100, PN10
PRO C10...
DN100, PN10
Suction connection
PRO V05...
DN50, PN10
PRO C05...
PRO V06...
DN65, PN10
PRO C06...
PRO V08...
DN80, PN10
PRO C08...
PRO V10...
DN100, PN10
PRO C10...
* Operating mode S350% is permitted if the necessary motor cooling is guaranteed
before the motor is switched on again! To ensure the required cooling, the motor must
be completely immersed for at least 1min.!
** S1 operation is dependent on the motor power. Observe and comply with the spe-
cification regarding “non-immersed” operating mode on the rating plate!
4.7 Type key
Example: Wilo-Rexa PRO V06DA-110/EAD1X2-T0015-540-P
PRO
Series
V
Impeller shape
V=vortex impeller
C=single-channel impeller
06
Nominal diameter of pressure connection
D
Hydraulic version:
D= suction side drilled acc. to DIN
N= suction side drilled according to ANSI
A
Hydraulics material version: standard
110
Hydraulics definition
E
Motor version: surface-cooled motor
A
“Motor” material version: standard
D
Seal
D=two mechanical seals
B=cartridge seal
1
IE-efficiency class (derived from IEC60034‑30)
X
Ex-rated
X=ATEX
F=FM
C=CSA-Ex
2
Number of poles
T
Mains connection version: M=1~, T=3~
0015
/10=Rated power P
2
in kW
5
Frequency mains connection: 5=50Hz, 6=60Hz
40
Code for rated voltage
P
Additional electrical equipment:
O=with bare cable end
P=with plug
4.8 Scope of delivery
Pump
Cable with plug or bare cable end
Single-phase current version with capacitor switchgear
Installation and operating instructions
4.9 Accessories
Suspension unit
Pump support foot

Table of Contents