Transportation and storage en
Installation and operating instructions Wilo-Rexa UNI 11
Example: Wilo-Rexa UNI V05/T06-540/P
V Impeller= vortex impeller
05 Nominal diameter of pressure connection
T Mains connection version: M=1~, T=3~
06 /10=Rated power P
2
in kW
5 Frequency mains connection: 5=50Hz, 6=60Hz
40 Code for rated voltage
P
Additional electrical equipment:
without= with free cable end
A= with float switch and plug
P= with plug
4.8 Scope of delivery
▪Pump with 10m cable
▪Single-phase version with
– Shockproof plug
– Float switch and shockproof plug
▪Three-phase version with
– Bare cable end
– Float switch and CEE plug
▪Installation and operating instructions
4.9 Accessories
▪Cable lengths in fixed length increments of 10m to
max. 30m in the single-phase current version or max.
50m in the three-phase version
▪Suspension unit
▪Level control devices
▪Fixation accessories and chains
▪Switchgear, relays and plugs
5 Transportation and storage
5.1 Delivery
After receiving the shipment, this must be checked im-
mediately for defects (damage, completeness). Defects
must be noted on the freight documentation! Further-
more, defects must be notified to the transport com-
pany or the manufacturer immediately on the day of
receipt of shipment. Subsequently notified defects can
no longer be asserted.
5.2 Transport
WARNING
Standing beneath suspended loads!
Never allow anyone to stand under suspended loads!
Danger of (serious) injuries caused by falling parts.
Loads may not be carried over work places where
people are present!
WARNING
Head and foot injuries due to lack of protect-
ive equipment!
Danger of (serious) injuries during work. Wear the
following protective equipment:
• Safety shoes
• Safety helmet must be used if lifting equipment
are used!
NOTICE
Only use lifting equipment in a technically
sound condition!
Only use lifting equipment in a technically sound
condition for lifting, lowering and transporting the
pump. Ensure that the pump does not become
jammed during lifting and lowering. Do not exceed
the max. permissible bearing capacity of the lifting
equipment!
CAUTION
Soaked packaging may tear!
As a result, the device may fall on the ground unpro-
tected and may be damaged. Soaked packaging
must be lifted carefully and replaced immediately!
Only remove the outer packaging at the place of util-
isation to ensure that the pump is not damaged during
transport. Use tear-proof plastic sacks of sufficient size
to package used pumps for transport in a leak-proof
manner.
The following points must also be observed: