EasyManuals Logo

Wilo Rexa UNI User Manual

Wilo Rexa UNI
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
Transportation and storage en
Installation and operating instructions Wilo-Rexa UNI 11
Example: Wilo-Rexa UNI V05/T06-540/P
V Impeller= vortex impeller
05 Nominal diameter of pressure connection
T Mains connection version: M=1~, T=3~
06 /10=Rated power P
2
in kW
5 Frequency mains connection: 5=50Hz, 6=60Hz
40 Code for rated voltage
P
Additional electrical equipment:
without= with free cable end
A= with float switch and plug
P= with plug
4.8 Scope of delivery
Pump with 10m cable
Single-phase version with
Shockproof plug
Float switch and shockproof plug
Three-phase version with
Bare cable end
Float switch and CEE plug
Installation and operating instructions
4.9 Accessories
Cable lengths in fixed length increments of 10m to
max. 30m in the single-phase current version or max.
50m in the three-phase version
Suspension unit
Level control devices
Fixation accessories and chains
Switchgear, relays and plugs
5 Transportation and storage
5.1 Delivery
After receiving the shipment, this must be checked im-
mediately for defects (damage, completeness). Defects
must be noted on the freight documentation! Further-
more, defects must be notified to the transport com-
pany or the manufacturer immediately on the day of
receipt of shipment. Subsequently notified defects can
no longer be asserted.
5.2 Transport
WARNING
Standing beneath suspended loads!
Never allow anyone to stand under suspended loads!
Danger of (serious) injuries caused by falling parts.
Loads may not be carried over work places where
people are present!
WARNING
Head and foot injuries due to lack of protect-
ive equipment!
Danger of (serious) injuries during work. Wear the
following protective equipment:
Safety shoes
Safety helmet must be used if lifting equipment
are used!
NOTICE
Only use lifting equipment in a technically
sound condition!
Only use lifting equipment in a technically sound
condition for lifting, lowering and transporting the
pump. Ensure that the pump does not become
jammed during lifting and lowering. Do not exceed
the max. permissible bearing capacity of the lifting
equipment!
CAUTION
Soaked packaging may tear!
As a result, the device may fall on the ground unpro-
tected and may be damaged. Soaked packaging
must be lifted carefully and replaced immediately!
Only remove the outer packaging at the place of util-
isation to ensure that the pump is not damaged during
transport. Use tear-proof plastic sacks of sufficient size
to package used pumps for transport in a leak-proof
manner.
The following points must also be observed:

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wilo Rexa UNI and is the answer not in the manual?

Wilo Rexa UNI Specifications

General IconGeneral
BrandWilo
ModelRexa UNI
CategoryWater Pump
LanguageEnglish

Related product manuals