en Disposal
94 WILO SE 2019-10
12 Disposal
12.1 Oils and lubricants
Operating fluid must be collected in suitable tanks and disposed of in accordance with
the locally applicable guidelines. Wipe up drips immediately!
12.2 Protective clothing
Used protective clothing must be disposed off in accordance with the locally applicable
guidelines.
12.3 Information on the collection of
used electrical and electronic
products
Proper disposal and appropriate recycling of this product prevents damage to the envi-
ronment and putting your personal health at risk.
NOTICE
Disposal in domestic waste is prohibited!
In the European Union this symbol may be included on the product, the packaging or
the accompanying documentation. It means that the electrical and electronic
products in question must not be disposed of along with domestic waste.
Please note the following points to ensure proper handling, recycling and disposal of
the used products in question:
ƒ Hand over these products at designated, certified collection points only.
ƒ Observe the locally applicable regulations!
Please consult your local municipality, the nearest waste disposal site, or the dealer who
sold the product to you for information on proper disposal. See
www.wilo‑recycling.com for more information about recycling.
Subject to change without prior notice!
13 Ex rating
This section contains further information on the operation of the pump in an explosive
atmosphere. All personnel must read this section. This section applies only to Ex-rated
pumps!
13.1 Identification of Ex-rated pumps
For use in explosive atmospheres, the pump must be marked as follows on the rating
plate:
ƒ “Ex” symbol of the corresponding approval
ƒ Ex classification
ƒ Certification number (depending on the approval)
The certification number, if required by the approval, is printed on the rating plate.
13.2 Protection class
The motor’s design version corresponds to the following protection classes:
ƒ Flameproof enclosure (ATEX)
ƒ Explosionproof (FM)
In order to limit the surface temperature, the motor must be equipped with at least one
temperature limiter (1-circuit temperature monitoring). It may also be equipped with a
temperature controller (2-circuit temperature monitoring).
13.3 Intended use
DANGER
Explosion due to pumping of explosive fluids!
Pumping of highly flammable and explosive fluids (gasoline, kerosene, etc.) in pure
form is strictly prohibited. There is a risk of fatal injury due to explosion! The pumps
are not designed for these fluids.
ATEX approval
The pumps are suitable for operation in potentially explosive atmospheres:
ƒ Device group: II
ƒ Category: 2, zone 1 and zone 2
These pumps must not be used in zone 0!