28 WILO SE 01/2009
2.17 action E4 Password 01 is required
To configure an optional sensor connected to input 4 as a
normally open contact (“closes”) or normally closed contact
(“opens”).
(For assignment of sensor, see menu 2.24)
opens
closes
closes
>closes <
2.21 max. time p
> 000 min
Password 01 is required
Setting of the maximum permissible continuous running time
for the pump
000 – 360 min
000 = deactivated
000 min.
<
2.24 connect E4 Password 01 is required
Selection of sensor assignment on input 4. Discrimination is
by means of an external resistor.
(For the action of the sensor, see menu 2.17)
back pressure
overflow
back pr.+overflow
back pressure
>back pressure <
2.25 alarm level Display of the alarm level for high-water level (flooding). The fol-
lowing formula applies: overflow height (menu 2.07) + 25 cm.
Menu 2.07+/-
100 cm
2.07 +25 cm
(Display of infor-
mation only)
> 2.07 + 025 cm <
2.50 choice-stop Password 02 is required
Display of switch-off logic adapted as appropriate to the
pump. F1 = 4 means switch-off pressure of 4 bar for the MC
304 pump.
F1 = 0
F1 = 4
F1 = 5
F1 = 9
F1 = 4
(Display of infor-
mation only)
> F1 = 4 <
2.53 p off var. Password 02 is required
Display of the variable pressure for pump switch-off. The
value is calculated as follows: set pressure for pump switch-
off (menu 2.13) + pressure change increment (menu 2.52)
(Menu 2.13 +/-
menu 2.52)
4.0+x.x bar
(MC 304)
(Display of infor-
mation only)
>4.0 ± x.x bar <
2.54 p actual Password 02 is required
Display of the actual pressure at the pressure sensor
Currently meas-
ured pressure
x.x bar
(Display of infor-
mation only)
>2.2 bar <
2.99 back with OK Return to the main menu Confirmation with
“OK” button
3Pump Nomi-
nal Values
Main menu: Pump Nominal Values
3.01 pump operat Display of the number of hours that the pump has been in
operation
xxxxxxx.xx h
(Display of infor-
mation only)
> 0000123,00 h
3.02 tank operat Display of the number of hours of operation with rainwater xxxxxxx.xx h
(Display of infor-
mation only)
> 0000103,00 h
3.03 topup water Display of the number of hours of operation with potable
water
xxxxxxx.xx h
(Display of infor-
mation only)
> 0000020,00 h <
3.99 back with OK Return to the main menu Confirmation with
“OK” button
5 Factory data con-
figuration
Main menu: Factory data configuration
5.01 data reset Resets the parameters to the factory settings Confirmation with
“OK” button and
then confirmation
of the query with
the arrow key
5.99 back with OK Return to the main menu Confirmation with
“OK” button
Menu Description Parameters Factory settings