What to do if Windhager Boiler displays AL 195?
- KKimberly SmithSep 18, 2025
If your Windhager Boiler displays error code AL 195, the boiler switches to burnout mode. Close the outer door.
What to do if Windhager Boiler displays AL 195?
If your Windhager Boiler displays error code AL 195, the boiler switches to burnout mode. Close the outer door.
How to fix the induced draught fan on a Windhager BioWIN?
To address issues with the induced draught fan on your Windhager Boiler: Clean the blower wheel and blower box. After cleaning, press the reset button.
How to troubleshoot no display on Windhager Boiler InfoWINplus?
If the display on your Windhager Boiler InfoWINplus is blank, the issue could be due to several reasons. First, check the cable connecting to the device and the building fuse to ensure there is electricity. Also, verify the device fuse and replace it if necessary. Furthermore, make sure the mains power plug is securely connected. If these steps don't resolve the issue, it is recommended to contact Windhager Customer Service or a heating technician.
What to do if Windhager Boiler displays AL 133?
If your Windhager Boiler displays error code AL 133, it means the boiler temperature is above 100 °C. To resolve this, check the system and filling pressure. Then, press the release button B7 on the control panel.
How to fix error IN 590 on Windhager Boiler?
To address error code IN 590 on your Windhager Boiler, remove ash, clean the boiler and burner, and then confirm the cleaning.
How to resolve error FE 390 on Windhager Boiler?
To address error code FE 390 on your Windhager Boiler, remove ash, clean the boiler and burner, and then confirm the cleaning.
What to do if Windhager Boiler displays FE 381?
If your Windhager Boiler displays error code FE 381, the enable time for the feed has been set too short. You should extend the enable time for the feed in the “Feed operating mode” menu item.
What to do if Windhager Boiler displays IN 438?
If your Windhager Boiler displays error code IN 438, it means a zone in the storage room is empty. Check the pellet supply in the storage room and press reset.
What to do if Windhager Boiler displays AL 005?
If your Windhager Boiler displays error code AL 005, it means the ash removal motor no longer moves or doesn't reach the end position. To resolve this, clean the burner pot and press reset.
What to do if Windhager Boiler displays IN 581?
If your Windhager Boiler displays error code IN 581, it means the integral fuel hopper is almost empty. To resolve this, refill the pellets.
Outlines the user's responsibilities for optimal boiler service and safety.
Details potential hazards associated with boiler operation and maintenance.
Describes the required periodic checks and certifications for system function.
Guides on how to manually operate the boiler and adjust setpoints.
Procedure to confirm boiler cleaning and restart the cleaning interval timer.
Summarizes the recommended intervals for cleaning and maintenance tasks.
Detailed steps for safely removing and emptying the ash pan.
Procedure for emptying the ash container on the BioWIN Exklusiv model.
Maintenance steps for the baffle plate, sensor, and down chute in the combustion chamber.
Instructions for cleaning the burner pot, including removing deposits and debris.
Guidance on inspecting and cleaning the blower wheel and its housing.
Troubleshooting steps for issues where the InfoWINplus display is blank or the boiler won't turn on.
Explains IN- messages related to pellet supply and cleaning prompts.
Troubleshooting for FE- messages concerning pellet feed issues.
Covers AL- messages related to various sensor, motor, and flap malfunctions.
| Fuel Type | Wood pellets |
|---|---|
| Dimensions (H x W x D) | Varies by model |
| Efficiency | Up to 95% |
| Automatic Cleaning | Automatic heat exchanger cleaning |
| Weight | 300-500 kg |