Operating Manual
FireWIN
windhager.com
Fully automatic pellet central heating boiler
for the living room and entire apartment
Performance range: 4,7 to 12 kW
Pellets
07/2012 092121/04

Table of Contents

Other manuals for Windhager FireWIN

Questions and Answers

  • C
    cmedinaAug 19, 2025
    What to do if the safety thermostat has tripped on my Windhager FireWIN Boiler?
    • H
      hhawkinsAug 20, 2025
      If the safety thermostat has tripped on your Windhager Boiler, it means the boiler temperature is above 100 °C, causing the boiler to enter burnout mode. You should check the water level or pressure in the heating system and refill or bleed the air as necessary.
  • G
    gfergusonAug 21, 2025
    Why is the combustion chamber pressure not stable in my Windhager FireWIN Boiler?
    • D
      Derek CraneAug 22, 2025
      If your Windhager Boiler's combustion chamber pressure is not stable, it could be due to several reasons: * Heating surface cover leaking: Check whether it is firmly closed. * Combustion chamber and ash door leaking: Check the seal and renew it if necessary. * Pressure measuring nipple blocked: Clear it. * Intake air line or induction opening blocked: Clear it. * Exhaust pipe or flue blocked: Clear it. * Combustion chamber pressure switch defective.
  • W
    wangamandaAug 25, 2025
    Why is the reserve supply container empty on my Windhager FireWIN Boiler?
    • J
      Jonathan Jimenez DVMAug 25, 2025
      If your Windhager Boiler indicates that the reserve supply container is empty, it is because the feed is outside the enable time. Extend the enable time for the feed in the 'Feed operating mode' menu item.
  • K
    Kristina WebbAug 26, 2025
    What to do if Windhager Boiler displays 'Reserve supply container empty'?
    • M
      Matthew JacobsAug 27, 2025
      If your Windhager Boiler displays 'Reserve supply container empty', it means that the reserve supply container is empty. Fill fuel into the fuel container.
  • D
    Darin GutierrezAug 28, 2025
    What to do if the cladding door is open on my Windhager Boiler?
    • T
      Tyler WebbAug 28, 2025
      If the cladding door is open on your Windhager Boiler, the burner will be locked. Close the cladding door to resolve this.
  • C
    Carol WilliamsAug 30, 2025
    What to do if there is no flame formation in control mode in Windhager FireWIN?
    • K
      Karen CopelandAug 30, 2025
      If your Windhager Boiler displays 'No flame formation in control mode', it means that the flame goes out in modulation mode. Clean the burner and the boiler.
  • W
    william62Sep 1, 2025
    Why is my Windhager FireWIN Boiler feed not sucking any pellets in?
    • K
      kyuSep 1, 2025
      If your Windhager Boiler is not sucking any pellets, it could be due to a few reasons: * No pellets at the suction wand: Set 'Wand switching' to 'automated' or select another wand. * Feed hose blocked: Clear it.
  • D
    daniel60Sep 3, 2025
    How to troubleshoot no display on InfoWIN for Windhager Boiler?
    • A
      andreswheelerSep 4, 2025
      If you are getting a 'No display on InfoWIN' error with your Windhager Boiler, here are a few things to check: 1. Electricity: Ensure the cable is properly connected and check the building fuse. 2. Device fuse: Check the device fuse and replace it if necessary. 3. InfoWIN plug: Make sure the plug is firmly connected. It's located on the side at the top behind the right side panel cladding.
  • S
    Samuel AndrewsSep 6, 2025
    What to do for excess temperature in the auger tube in Windhager Boiler?
    • S
      Sharon LesterSep 6, 2025
      If you encounter 'Excess temperature in the auger tube' on your Windhager Boiler, the boiler switches to burnout mode. Check the burner and remove all pellets from the burner pot.
  • C
    christopherbrooksSep 8, 2025
    What to do if there is no negative pressure in the combustion chamber of my Windhager Boiler?
    • M
      Michael RiveraSep 8, 2025
      If you are experiencing 'No negative pressure in the combustion chamber' with your Windhager Boiler, the boiler switches to burnout mode. Check if the heating surface cover is leaking and ensure it is firmly closed.

Summary

1. Important information for system operators

1.2 Safety precautions

Details on caution symbols and safety instructions for operation.

1.3 Sources of danger

Identifies potential hazards like fire, power failure, and burner pot issues.

2. Operation

2.5 Operating modes

Explains various operational modes like OFF, ON, Pellet feed, and Solid fuel/buffer.

3. Care, cleaning and maintenance

3.1 Overview of intervals between cleaning (maintenance)

Provides a summary of cleaning and ash removal intervals for different FireWIN models.

3.6 Combustion chamber

Covers cleaning procedures for the combustion chamber and burner pot.

4. Troubleshooting

4.1 No display on InfoWINplus

Troubleshooting steps for when the InfoWINplus display is not working.

4.2 IN- messages

Explains common IN messages related to pellet supply and boiler status.

4.3 FE- messages

Details FE messages related to auger, feed, probe switching, and pressure.

4.4 AL - messages

Covers AL messages related to ash removal, auger, fan, air intake, and safety switches.