58
3. Care, cleaning and maintenance
3.10 Pellet storage room or storage container
(FireWIN Premium and Exklusiv)
Information!
When entering the pellet storage room or storage container do not stand on the pellets around the
suction probe.
Before filling the pellet storage room or storage container, check the following:
- whether the storage room is free of foreign bodies.
- whether a lot of dust has settled on the floor over time.
Please note: A layer of dust on top of the pellets is normal because dust present migrates to the surface when
the pellets gush out during removal.
- whether pellets have swelled up against the wall if the storage room is not fully dry.
Tip
Pellet dust is totally organic and can therefore be disposed of as organic waste.
Leading pellet suppliers recommend fully emptying the storage room every 2–3 years. You can
deactivate automatic changeover between the three suction probes using the InfoWINplus (see
section 2.8.1.3). This allows you to fully empty the storage room for one probe (i.e. 1/3 of the sto-
rage room). You can then continue heating with the other two suction probes. If you perform this
task every year with a different want, you will “replace” your entire supply of pellets every 3 years.
Attention!
Please also note the hazard information in section 1.3.4 Entering the pellet storage room, storage
container.