CLEANING PROCEDURE
CLIPPER 86038240
3-9
STEP
5
STEP
6
After cleaning, turn off all controls, return
brush to storage position and carefully unplug
machine.
STEP
4
STEP
1
Use right side of machine for cleaning against
walls.
OFF
OFF OFF
SOLUTION
INTAKE COVER
VACUUM
INTAKE COVER
O
R
Start at wall closest to power outlet. For large
areas flip handle and operate machine in
parallel passes, overlapping brush path. Clean
perimeter last.
During operation, observe the following: The
Clipper is equipped with clear internal covers to
facilitate operator viewing of dirty solution and
vacuum air flow.
During operation, observe the vacuum intake
cover. Large amounts of water or foam
entering the vacuum system can damage the
vacuum motor. If you notice either condition,
shut down the machine immediately. Empty
recovery tank and/or add defoamer to recovery
tank.