REPLACING FILTERS
CLEANING CARE
Cleaning the Filters:
Use a vacuum cleaner or soft brush to clean the Pre-Filter
If it is excessively soiled, rinse in room temperature water.
Do not use detergent or soap.
Allow the filter to dry for 24 hours or more before using.
Intervals between filter cleaning may vary depending on
the air quality in the environment.
Do not use hot water over 40°C.
Particle Sensors Care
1.
Use a damp cotton swab to wipe the
lens and intake area of the Particle
Sensor.
To clean the sensor area, use
only water. Do not use volatile
substances such as alcohol or
acetone.
2.
Wipe away any remaining moisture
with a dry cotton swab.
NOTICE
Do not use benzene, alcohol, or other volatile fluids,
which may cause damage or discoloration.
Cleaning the Exterior & Interior:
Wipe with a soft damp cloth using room temperature water.
Afterwards, wipe it down with a clean, dry cloth.
Open the front panel and clean the interior with a vacuum
cleaner.
For optimal performance, clean every 1-2 months.
NOTICE
When cleaning the unit, always unplug the power cord
first and then wait until the unit has cooled down.
Never disassemble, repair, or modify this unit yourself.
Do not use flammable sprays or liquid detergents.
Do not allow children to clean or maintain the unit.
Before cleaning or maintaining, ensure unit is unplugged.
item: 116130
After replacing a filter, press
the Filter Reset Button for at
least 5 seconds.