Assembly instructions | 89014665; 2022-04 | 3
4 Install conductance-controlled dosing device
NOTE
Danger of rusting and clogged jets caused by drilling swarf!
Rusting drilling swarf can also cause “stainless steel” to begin to rust.
Ø Remove drilling swarf from the interior of the warewasher.
UF-M / UF-L
UF-XL
2
78,5
30
78,5
30
300
= =
1
2
170
300
1
4.1 Install measuring electrode
Ø Open door.
Ø Remove the lower wash arms, strainer and filter cylinder.
Ø Line the interior of the tank with cloths or suitable paper to catch drilling swarf.
Ø Determine the size of the drill hole according to the measuring electrode.
Ø Drill a hole for the measuring electrode at position (1).
Ø Deburr the drillhole.
Ø Remove drilling swarf from the interior of the warewasher.
Ø Install measuring electrode.
Ø Lead the connection cable of the measuring electrode to the dosing device.
4.2 Assemble injection hose for dosing device for powder
Ø Open door.
Ø Remove the lower wash arms, strainer and filter cylinder.
Ø Line the interior of the tank with cloths or suitable paper to catch drilling swarf.
Ø Determine the size of the drill hole according to the flushing nozzle.
Ø Drill a hole for the inflow point at position (2).
Ø Deburr the drillhole.
Ø Remove drilling swarf from the interior of the warewasher.
Ø Mount the flushing nozzle on the warewasher.
Ø Fasten the injection hose to the flushing nozzle with a hose clamp.
Ø Seal openings in cover and attach edge protection.