After send instruction, the module turn back a data packet 0x55 0x71. There are register
address and 7 registers data (Fixed upload 8 registers). Return data format please refer to 7.1.2.
6.2.2 Accelerometer Calibration and Magnetic Calibration
FF AA 01 01 00
Accelerometer Calibration
FF AA 01 05 00
Accelerometer Calibration L
FF AA 01 06 00
Accelerometer Calibration R
FF AA 01 07 00
Magnetic Calibration
FF AA 01 00 00
Magnetic Calibration Finish
6.2.3 Save Settings
FF AA 00 SAVE 00
Save Settings
SAVESet
0Save current configuration
1Restore default configuration and save
6.2.4 Set Return Rate
FF AA 03 RATE 00
Set return rate
RATEreturn rate
0x010.1Hz
0x020.5Hz
0x031Hz
0x042Hz
0x055Hz
0x0610Hzdefault
0x0720Hz
0x0850Hz
0x09100Hz
Set Port D0
FF AA 0E D0MODE 00
Set port D0
D0MODED0