WMF 2000 S Service Manual Edition 11/2010
WMF 2000 S Service Manual
Report
Display
Descr.
Entry ring mem.
Entry display
Comment
No. malfunction
memory
130 F130 General current
malfunction
√ √ Short circuit if
immediately at
switching-on
24/30 V present
28
not implemented
149 F149 General voltage
malfunction
√ √ If short circuit is present
in 24/30 V systems
86
161 F161 flowmeter
malfunction during
brewing
√ √ 241
162 F162 flowmeter
malfunction during
cleaning
√ √ 242
163 F163 flowmeter
malfunction during
checking
√ √ 243
164 F164 flowmeter
malfunction during hot
water dosage
√ √ 244
165 F165 flowmeter
malfunction during choc
dosage
√ √ 245
166 F166 flowmeter
malfunction during DK
feeding
√ √ 246
167 F167 flowmeter
malfunction during
descaling
√ √ 167
170 F170 Automatic steam
wand sensor short cut
√ √ 336
171 F171 Automatic steam
wand sensor interruption
/ not connected
√ √ 335
186 F186 timeout during
steam boiler filling
√ √ 247
187 F187 Steam boiler sensor
damage