27
WMF 2000 S Service Manual Edition 11/2010
WMF 2000 S Service Manual
Report
Display
Descr.
Entry ring mem.
Entry display
Comment
No. malfunction
memory
188 F188 Excess temperature
in steam boiler
√ √ 231
189 F189 Heating-time steam
boiler
√ √ 43
9061 Standby Event √ Coming and going 61 Coming and going
9062 Reset Event! √ Coming and going 62
9104 Timer function not
possible
√ √ Machine cannot switch
off due to cleaning in
progress
9104
Fifo was deleted √ √ 9118
Defaults into RAM √ √ 9119
Defaults into flash √ √ 9120
Machine cleaning in
progress
√ internal 9125 internal
Milk foam cleaning in
progress!
√ internal 9126 internal
Cleaning was interrupted √ √ due to an error in the
cleaning program
9136 Display cleaning
obligation
Mixer cleaning in progress √ internal 9180
AD-transformer ready!
(for developers only)
√ √ internal 9236
9248 Malfunction in level
sensor
√ √ 9248
9256 Auto detect malfunction:
Right grinder not
detected
√ √ 9256
9257 Auto detect malfunction:
brewing-valve not
detected
√ √ 9257
9258 Auto detect malfunction:
Oscillating pump not
detected
√ √ 9258
9259 Auto detect malfunction:
Release valve not
detected
√ √ 9259
9269 Auto detect malfunction:
Fan not detected
√ √ 9260