Operating instructions
Gas red condensing boiler
CGB-11 Boiler
CGB-20 Boiler
CGB-24 Boiler
CGB-35 Boiler
CGB-50 Boiler
CGB-75 Boiler
CGB-100 Boiler
CGB-K-20 Combi boiler
CGB-K-24 Combi boiler
Wolf GmbH · Postfach 1380 · 84048 Mainburg · Tel. 08751/74-0 · Fax 08751/741600 · Internet: www.wolf-heiztechnik.de
Art.-Nr. 30 61 345 Salvo modiche 06/09 GB

Other manuals for Wolf CGB-11

Questions and Answers

  • G
    gfosterSep 23, 2025
    What does it mean if the LED is constantly red on my Wolf CGB-11?
    • K
      Kristin RossSep 23, 2025
      If the LED on your Wolf Boiler is constantly red, it indicates that the ionization lead is shorted out or the ionization electrode is earthed (housing). Check the ionization lead and the position of the electrode to the burner, then press the reset button.
  • T
    thompsonandrewAug 25, 2025
    How to fix TBV excess temperature on Wolf CGB-11?
    • D
      Diana WarrenAug 25, 2025
      If your Wolf Boiler shows a TBV excess temperature error, it means the flow temperature has exceeded the limit for TBV shutdown, possibly due to a severely contaminated heat exchanger. To resolve this, check the system pressure and heating circuit pump. Also, check the HC pump step switch, vent the heating system, and then press the reset button.
  • S
    Sarah LynchAug 25, 2025
    What to do if my Wolf CGB-11 Boiler shows TW excess temperature?
    • B
      Bradley MillerAug 26, 2025
      If your Wolf Boiler displays a TW excess temperature error, indicating that the flow/return temperature has exceeded the limit for TW shutdown, check the system pressure and vent the heating system. Additionally, set the pump to stage 2 or 3.
  • L
    Lindsey KellyAug 27, 2025
    What to do if my Wolf Boiler gas fan doesn't stop?
    • R
      rharmonAug 27, 2025
      If the gas fan in your Wolf Boiler does not stop, check the gas fan supply cable and the gas fan itself. After checking, press the reset button.
  • J
    Jeremy BanksAug 27, 2025
    What causes TBA excess temp. in Wolf CGB-11?
    • C
      christopher64Aug 27, 2025
      If your Wolf Boiler is showing TBA excess temp, it means that the flue gas temperature has exceeded the limit for TBA shutdown. Check for correct installation of the combustion chamber pot.
  • J
    Julian LeeSep 13, 2025
    What to do if my Wolf CGB-11 shows Gas valve „2“ fault?
    • D
      Debbie CohenSep 13, 2025
      If your Wolf Boiler displays a Gas valve "2" fault, and a flame is recognised 15 seconds after burner operation, even if gas valve 2 has received a shutdown command, replace the gas combination valve.
  • D
    danielle13Sep 12, 2025
    What does Incorrect BCC mean on Wolf Boiler?
    • J
      jennifer67Sep 12, 2025
      If your Wolf Boiler shows Incorrect BCC, it means that the boiler coding card is incompatible with the control unit PCB, so refit the correct parameter plug.
  • R
    rebecca50Sep 12, 2025
    What to do if my Wolf Boiler shows Gas valve „1“ fault?
    • A
      Alexander SpencerSep 12, 2025
      If your Wolf Boiler displays a Gas valve "1" fault, and a flame is recognized 15 seconds after burner operation even if gas valve 1 has received a shutdown command, replace the gas combination valve.
  • S
    Steven GarzaSep 4, 2025
    What to do if the flow sensor is faulty in my Wolf Boiler?
    • K
      Kayla SullivanSep 4, 2025
      If the flow sensor in your Wolf Boiler is faulty, meaning the flow temperature sensor or lead is faulty, check the lead and the flow sensor.
  • R
    Ryan RamosSep 2, 2025
    What to do if my Wolf CGB-11 has a fault in the 24 VAC supply?
    • S
      Sara MasseySep 2, 2025
      If your Wolf Boiler indicates a fault in the 24 VAC supply, meaning the 24 V AC supply is outside the permissible range (e.g., short circuit), check the three-way valve and the gas fan.

Summary

Safety instructions

If you smell gas

Actions to take and precautions when gas is detected, emphasizing risks of poisoning, suffocation, and explosion.

If you smell flue gas

Steps to follow if flue gas is detected, focusing on risks of poisoning.

When changing a fuse

Procedure and electrical safety precautions for changing a fuse, warning against electrocution.

Frost protection

Information on automatic frost protection and risks associated with freezing, like water damage.

Balanced flue system

Risks related to ice formation on the balanced flue pipe and prevention measures, warning of injury.

Installation and maintenance information

Installation;modifications

Guidelines for installation and modifications by approved contractors, prohibiting modification of gas components.

Wartung

Emphasis on regular annual maintenance by qualified personnel and safety checks after service.

Water connections and gas supply connection

Control unit operation

Illuminated ring as status indicator

Explanation of the status indicator lights (green, yellow, red) for different operational states.