Installationinstructionsforcontractors
Wall mounted gas condensing boiler
CGB-2 wall mounted gas condensing boiler
CGB-2K wall mounted gas condensing combi boiler
CGB-2-14
CGB-2(K)-20
CGB-2(K)-24

Other manuals for Wolf CGB-2K-24

Questions and Answers

  • R
    Rebecca ThompsonSep 23, 2025
    What to do if external fault at programmable Input E1 on Wolf CGB-2K-24 Boiler?
    • A
      Andrew HayesSep 23, 2025
      If your Wolf Boiler displays 'External fault at programmable Input E1', it means an external fault has been reported at programmable input E1 because the fault message contact at E1 has opened. Rectify the external fault and check the lead. Acknowledge the fault message afterward.
  • R
    rfranklinAug 23, 2025
    What to do if there is flame failure in Wolf CGB-2K-24 Boiler?
    • S
      Sarah DixonAug 23, 2025
      If the Wolf Boiler shows a 'Flame failure' error, it could be due to several reasons. First, verify the gas type setting on both the gas valve and the AM/BM. Then, check the gas supply pressure. Inspect the condition of the ionization electrode, cleaning or replacing it if necessary, and ensure its gap and position are correctly set. Finally, examine the flue path inside and outside the appliance for any leaks or blockages.
  • A
    Anna KellyAug 25, 2025
    How to fix HLSC excess temp on Wolf CGB-2K-24 Boiler?
    • J
      Joanne BennettAug 26, 2025
      If your Wolf Boiler displays 'HLSC excess temp,' it indicates that the temperature at the heat exchanger cover has exceeded 185 °C. Check the cables and plugs connected to the high limit safety cut-out (HLSC). If the electrical connections are fine but there's still no function, replace the HLSC. Another possible cause is a contaminated combustion chamber, in which case, clean or replace the combustion chamber.
  • A
    Ashley KimAug 26, 2025
    What to do if TL excess temp on Wolf CGB-2K-24?
    • E
      esparzakathyAug 27, 2025
      If your Wolf Boiler shows a 'TL excess temp' error, it means one of the temperature sensors eHLSC1 or eHLSC2 on the combustion chamber has exceeded the high limit safety cut-out limit (108 °C). Check the system pressure and vent the heating circuit. Inspect the cables and plugs of the temperature limiter (eHLSC), and if they are OK but there's no function, replace the eHLSC. Also, check if the pump is running; if not, check its cables and plugs, and if the electrical connection is OK but it's still not working, replace the pump.
  • T
    Thomas DunnAug 27, 2025
    What to do if boiler sensor is faulty in Wolf Boiler?
    • K
      Kelly HardyAug 27, 2025
      If your Wolf Boiler displays the message 'Boiler sensor faulty' it could be due to excess temperature in the flow (Boiler sensor > 100 °C). First, check if the pump is running. If it is not, check the cables and plugs and if the electrical connection is OK but there is still no function, replace the pump. Another solution is to increase the minimum pump speed. Also, check the leads and plug-in connections of the boiler sensor, and if they are OK but there is still no function, replace the boiler sensor.
  • K
    Kevin WrightSep 17, 2025
    What causes timeout calibration error on Wolf CGB-2K-24?
    • A
      Andrea ShannonSep 18, 2025
      If your Wolf Boiler displays 'Timeout calibration', it means the heating appliance cannot carry out calibration. Check the flue path inside and outside the appliance for any blockages related to flue gas recirculation. Ensure the fan and its wiring are intact. Ensure adequate heat transfer by opening heating circuits.
  • C
    changkurtSep 14, 2025
    What causes GLV actuators error on Wolf Boiler?
    • P
      Phillip DukeSep 14, 2025
      If your Wolf Boiler displays 'GLV actuators' there may be several causes. Check the flue path inside and outside the appliance for leaks or blockages related to flue gas recirculation and check for wind effect. Verify the gas type setting on the gas valve and the AM/BM-2. Remove the gas valve retainer and check that the correct gas restrictor is fitted. Check the fan for bearing damage and inspect the cables, plug-in connections, power supply, and switching.
  • K
    Kelsey TurnerSep 16, 2025
    What to do if GCV relay test failed on Wolf CGB-2K-24?
    • M
      Michelle BakerSep 16, 2025
      If your Wolf Boiler displays 'GCV relay test', it means the valve test failed and the gas valve is faulty. Replace the gas valve.
  • K
    kmedinaSep 6, 2025
    Why is fan speed high on Wolf CGB-2K-24 Boiler?
    • T
      Tami HallSep 6, 2025
      If the Wolf Boiler displays 'Fan speed >', it means the fan does not stop. Check the fan's cables, plug-in connections, power supply, and switching. If the fault occurs repeatedly, replace the fan.
  • J
    Justin TylerSep 3, 2025
    What to do if outside sensor is faulty in Wolf CGB-2K-24?
    • J
      John WhiteSep 3, 2025
      If your Wolf Boiler displays 'Outside sensor faulty,' it means that the outside sensor or sensor lead has a short circuit or break. For the eBus outside temperature sensor, refer to its instructions. Similarly, for a wireless outside sensor, consult its specific instructions.

Summary

Safety instructions

Danger from gas

Provides immediate actions to take if gas odor is detected.

Danger from live electrical components

Warns about the risk of electrocution from live electrical parts.

Risk of scalding

Advises caution due to hot water and potential scalding.

Risk of burns

Warns about hot boiler components causing burns.

Working on the system

Details safety procedures for working on the boiler system.

Electronic gas;air mixture

Standards and regulations

Positioning

Minimum installation clearances

Specifies minimum clearances required around the boiler for installation.

Gas connection

Licensed gas fitter requirement

Emphasizes the need for a licensed fitter for gas connections.

Air;flue gas routing

Electrical connection

Electrical connection requirements

Details electrical connection requirements and safety warnings.

Flue gas damper;ventilation air damper electrical connection

HG control parameters

Parameter description

Filling the heating system and trap

Heating system filling procedure

Step-by-step guide for filling the heating system and trap.

Draining the heating system

Heating system draining steps

Step-by-step instructions for draining the heating system.

Determining and changing the gas type

Changing gas type to LPG

Details the procedure for changing the gas type to LPG.

Checking the gas supply pressure

Gas supply pressure check procedure

Step-by-step guide for checking gas supply pressure.

Adjusting the maximum heating output

Checking the combustion parameters

Converting from combi boiler to boiler with cylinder

Authorised contractor conversion requirement

States that conversion must be done by authorized contractors.

Setting the flow limiter

High efficiency pump function description

Commissioning report

Commissioning steps checklist

Lists steps for commissioning and fields for test values.

Safety devices

Temperature monitoring safety devices

Describes safety devices related to temperature monitoring.

System pressure monitoring safety devices

Explains safety devices for monitoring system pressure.

Technical information, air;flue gas routing

Tightness test on appliance connections

Details tightness testing for connections to adjacent appliances.

Technical information, underfloor heating;DHW circulation

Reset

Appliance parameter reset procedure

Describes that a parameter reset returns settings to factory defaults.

Troubleshooting

General troubleshooting information

General guidelines for troubleshooting and safety precautions.

Procedure for handling faults

Steps to follow when a fault occurs.

Troubleshooting warning messages

HCM-2 wiring diagram

HCM-2 wiring diagram details

Shows the wiring diagram for the HCM-2 module.

GBC-e wiring diagram

GBC-e wiring diagram details

Displays the wiring diagram for the GBC-e module.

Technical parameters according to EU regulation no. 813;2013

Wolf CGB-2K-24 Specifications

General IconGeneral
TypeCondensing Boiler
Max. Heat Output (80/60 °C)24 kW
Efficiency (Hs)98%
NOx Class6
Fuel TypeNatural Gas