Installationinstructionsforcontractors
Wall mounted gas condensing boiler
CGB-2 wall mounted gas condensing boiler
CGB-2K wall mounted gas condensing combi boiler
CGB-2-14
CGB-2(K)-20
CGB-2(K)-24

Other manuals for Wolf CGB-2K-24

Questions and Answers

  • R
    Renee GilbertSep 7, 2025
    Why calibration factory limit not reached on Wolf CGB-2K-24 Boiler?
    • L
      Lisa BrownSep 7, 2025
      If your Wolf Boiler displays 'Calibration factory limit' and the minimum limit was not reached, it could be due to flue gas recirculation issues. Check the flue path inside and outside the appliance for any leaks or blockages. Additionally, have customer service set the IO default value to the factory setting. Another possible cause is a corroded or bent ionization electrode, so check its condition and clean or replace it if necessary. Lastly, a wiring error on the HCM-2 (low voltage side) could be the culprit, so check the electrical connection of the HCM-2 low voltage side.
  • D
    donald09Aug 22, 2025
    What to do if no flame is established in Wolf CGB-2K-24 Boiler?
    • H
      hjonesAug 22, 2025
      If the Wolf Boiler displays 'No flame established', it could be due to several reasons. First, ensure the gas supply is properly connected and the gas valve is open. Next, inspect the ionization electrode for its position and condition, adjusting or replacing it if needed. Also, check the position of the ignition electrode and adjust if necessary, along with examining the ignition transformer and wiring. Verify that the HG44 curves are set to the standard value. Finally, check that the gas valve opens; if it doesn't, check the cables and plugs and repeat the test. If the gas valve is faulty, replace it.
  • L
    Lauren TannerSep 4, 2025
    Why is fan speed low on Wolf CGB-2K-24?
    • J
      Jeffrey FoxSep 5, 2025
      If your Wolf Boiler displays 'Fan speed
  • J
    Justin TylerSep 3, 2025
    What to do if outside sensor is faulty in Wolf CGB-2K-24?
    • J
      John WhiteSep 3, 2025
      If your Wolf Boiler displays 'Outside sensor faulty,' it means that the outside sensor or sensor lead has a short circuit or break. For the eBus outside temperature sensor, refer to its instructions. Similarly, for a wireless outside sensor, consult its specific instructions.
  • T
    Taylor PierceSep 2, 2025
    What to do if return sensor is faulty in Wolf CGB-2K-24?
    • J
      Janet WilliamsSep 2, 2025
      If your Wolf Boiler displays 'Return sensor faulty', it indicates that the return sensor or sensor lead has a short circuit or break, or the return sensor temperature is above 100 °C. Check the leads and plug-in connections of the return sensor. If they are OK and there is still no function, replace the return sensor.
  • T
    thomasleeAug 31, 2025
    What to do if DHW sensor is faulty in Wolf CGB-2K-24 Boiler?
    • C
      Cassandra SmithSep 1, 2025
      If your Wolf Boiler shows 'DHW sensor faulty', it means that the DHW sensor (cylinder sensor) or sensor lead has a short circuit or break, or the DHW-sensor temperature is above 99 °C. Check the leads and plug-in connections of the DHW temperature sensor. If they are OK, replace the sensor.
  • T
    Tara RoweAug 30, 2025
    What to do if flue gas sensor is faulty in Wolf CGB-2K-24?
    • L
      loricarrilloAug 30, 2025
      If your Wolf Boiler displays 'Flue gas sensor faulty,' it indicates that the flue gas sensor or sensor lead has a short circuit or break. Check the leads and plug-in connections of the flue gas temperature sensor. If the electrical connection is OK but there is no function, replace the sensor.
  • A
    Allen BlackAug 29, 2025
    How to fix eHLSC sensor faulty on Wolf Boiler?
    • C
      Christine GomezAug 29, 2025
      If your Wolf Boiler indicates 'eHLSC sensor faulty', it means that the temperature sensor eHLSC1, eHLSC2 on the combustion chamber or sensor lead has a short circuit or break. Check the leads and plug-in connections on the eHLSC on the combustion chamber. If the electrical connection is OK but there's no function, replace the eHLSC.
  • T
    Thomas DunnAug 27, 2025
    What to do if boiler sensor is faulty in Wolf Boiler?
    • K
      Kelly HardyAug 27, 2025
      If your Wolf Boiler displays the message 'Boiler sensor faulty' it could be due to excess temperature in the flow (Boiler sensor > 100 °C). First, check if the pump is running. If it is not, check the cables and plugs and if the electrical connection is OK but there is still no function, replace the pump. Another solution is to increase the minimum pump speed. Also, check the leads and plug-in connections of the boiler sensor, and if they are OK but there is still no function, replace the boiler sensor.
  • A
    Ashley KimAug 26, 2025
    What to do if TL excess temp on Wolf CGB-2K-24?
    • E
      esparzakathyAug 27, 2025
      If your Wolf Boiler shows a 'TL excess temp' error, it means one of the temperature sensors eHLSC1 or eHLSC2 on the combustion chamber has exceeded the high limit safety cut-out limit (108 °C). Check the system pressure and vent the heating circuit. Inspect the cables and plugs of the temperature limiter (eHLSC), and if they are OK but there's no function, replace the eHLSC. Also, check if the pump is running; if not, check its cables and plugs, and if the electrical connection is OK but it's still not working, replace the pump.

Summary

Safety instructions

Danger from gas

Provides immediate actions to take if gas odor is detected.

Danger from live electrical components

Warns about the risk of electrocution from live electrical parts.

Risk of scalding

Advises caution due to hot water and potential scalding.

Risk of burns

Warns about hot boiler components causing burns.

Working on the system

Details safety procedures for working on the boiler system.

Electronic gas;air mixture

Standards and regulations

Positioning

Minimum installation clearances

Specifies minimum clearances required around the boiler for installation.

Gas connection

Licensed gas fitter requirement

Emphasizes the need for a licensed fitter for gas connections.

Air;flue gas routing

Electrical connection

Electrical connection requirements

Details electrical connection requirements and safety warnings.

Flue gas damper;ventilation air damper electrical connection

HG control parameters

Parameter description

Filling the heating system and trap

Heating system filling procedure

Step-by-step guide for filling the heating system and trap.

Draining the heating system

Heating system draining steps

Step-by-step instructions for draining the heating system.

Determining and changing the gas type

Changing gas type to LPG

Details the procedure for changing the gas type to LPG.

Checking the gas supply pressure

Gas supply pressure check procedure

Step-by-step guide for checking gas supply pressure.

Adjusting the maximum heating output

Checking the combustion parameters

Converting from combi boiler to boiler with cylinder

Authorised contractor conversion requirement

States that conversion must be done by authorized contractors.

Setting the flow limiter

High efficiency pump function description

Commissioning report

Commissioning steps checklist

Lists steps for commissioning and fields for test values.

Safety devices

Temperature monitoring safety devices

Describes safety devices related to temperature monitoring.

System pressure monitoring safety devices

Explains safety devices for monitoring system pressure.

Technical information, air;flue gas routing

Tightness test on appliance connections

Details tightness testing for connections to adjacent appliances.

Technical information, underfloor heating;DHW circulation

Reset

Appliance parameter reset procedure

Describes that a parameter reset returns settings to factory defaults.

Troubleshooting

General troubleshooting information

General guidelines for troubleshooting and safety precautions.

Procedure for handling faults

Steps to follow when a fault occurs.

Troubleshooting warning messages

HCM-2 wiring diagram

HCM-2 wiring diagram details

Shows the wiring diagram for the HCM-2 module.

GBC-e wiring diagram

GBC-e wiring diagram details

Displays the wiring diagram for the GBC-e module.

Technical parameters according to EU regulation no. 813;2013

Wolf CGB-2K-24 Specifications

General IconGeneral
TypeCondensing Boiler
Max. Heat Output (80/60 °C)24 kW