What does CRC fault, BCC mean on Wolf CGB-11 Boiler?
- MMichael LevineSep 10, 2025
If your Wolf Boiler displays a CRC fault, BCC, it indicates a faulty boiler coding card, so replace the parameter plug.
What does CRC fault, BCC mean on Wolf CGB-11 Boiler?
If your Wolf Boiler displays a CRC fault, BCC, it indicates a faulty boiler coding card, so replace the parameter plug.
What to do if return sensor is faulty in my Wolf Boiler?
If the return temperature sensor in your Wolf Boiler is faulty, meaning the return temperature sensor or lead is faulty, check the lead and replace the return sensor.
What to do if outside temp sensor is faulty in my Wolf CGB-11?
If the outside temperature sensor in your Wolf Boiler is faulty, meaning the outside temperature sensor or lead is faulty, check the lead and the outside temperature sensor.
What to do if my Wolf CGB-11 Boiler has no flame?
If no flame is established during the burner start in your Wolf Boiler, check the gas supply pipe and open the gas shut-off valve if needed. Also, inspect the ignition electrode and cable. Finally, press the reset button.
What does CRC defaul values fault mean on my Wolf Boiler?
If your Wolf Boiler displays a CRC default values fault, it indicates that the EEPROM record "Master reset" is invalid. To resolve this, replace the control PCB.
What to do if the flow sensor is faulty in my Wolf Boiler?
If the flow sensor in your Wolf Boiler is faulty, meaning the flow temperature sensor or lead is faulty, check the lead and the flow sensor.
What does a CRC fault gas fired mean on a Wolf CGB-11 Boiler?
If your Wolf Boiler displays a CRC fault gas fired, it indicates that the EEPROM record "Gas fried condensing boiler" is invalid. To resolve this, switch the power supply OFF and then ON again; if unsuccessful, replace the control PCB.
What to do if my Wolf CGB-11 has a fault in the 24 VAC supply?
If your Wolf Boiler indicates a fault in the 24 VAC supply, meaning the 24 V AC supply is outside the permissible range (e.g., short circuit), check the three-way valve and the gas fan.
What to do if my Wolf Boiler shows a flame pretence error?
If your Wolf Boiler indicates a flame pretence error, meaning a flame is recognized before the burner starts, press the reset button.
What does a CRC fault burner mean on a Wolf CGB-11 Boiler?
If your Wolf Boiler displays a CRC fault burner, it indicates that the EEPROM record "Boiler" is invalid. To resolve this, switch the power supply OFF and then ON again. If the issue persists, replace the control PCB.
Actions to take and precautions when gas is detected, emphasizing risks of poisoning, suffocation, and explosion.
Steps to follow if flue gas is detected, focusing on risks of poisoning.
Procedure and electrical safety precautions for changing a fuse, warning against electrocution.
Information on automatic frost protection and risks associated with freezing, like water damage.
Risks related to ice formation on the balanced flue pipe and prevention measures, warning of injury.
Guidelines for installation and modifications by approved contractors, prohibiting modification of gas components.
Emphasis on regular annual maintenance by qualified personnel and safety checks after service.
Explanation of the status indicator lights (green, yellow, red) for different operational states.