4
W
ICBDF304
OLF
330 mm
LOCATION OF
ELECTRICAL
914 mm
937 mm
TO
COOKING
SURFACE
600 mm min
COUNTERTOP TO
COMBUSTIBLE
MATERIALS
VENTILATION HOOD
457 mm min
TO COUNTERTOP
LOCATION OF GAS AND
ELECTRICAL EXTENDS 57 mm
ON FLOOR FROM BACK WALL
762 mm
FINISHED ROUGH
OPENING WIDTH
83 mm
216
mm
254 mm
LOCATION
OF GAS
SUPPLY
600 mm min TO
914 mm max
TO BOTTOM OF
VENTILATION HOOD
ISLAND INSTALLATIONS: 305 mm MINIMUM
CLEARANCE FROM BACK OF RANGE TO
COMBUSTIBLE REAR WALL ABOVE COUNTERTOP–
911
mm
937 mm
OVERALL
HEIGHT TO
COOKING
SURFACE*
Overall Width 759 mm
Overall Height
(to cooking surface) 937 mm
Overall Depth 749 mm
Opening Width 762 mm
DUAL FUEL RANGE
IMPORTANT NOTE: In non-island applications,
a minimum 127 mm riser is required for model
ICBDF304.
Note A:
Side clearances. If the distance
measured from the periphery of the
nearest burner to any vertical surface
is less than 200 mm, the surface shall
be protected in accordance with
AS/NZ5601.
Note B:
The rangehood fitted above the
cooktop must be installed according
to the installation instructions for
the rangehood. A minimum
distance of 750 mm is required for a
range hood and 750 mm for an
exhaust fan
.