Figure 3-31. Glass Top Removal
Figure 3-32. Control Board Removal
Control Board
Support
Component Removal
Induction Range (IR) Series
Induction Range (IR) Series
3-13
#827176 - Revision A.1 - December, 2016
Glass Top Removal
To remove the glass top, first remove the induction
cooktop from the range, then:
Use a small flat blade screw driver or putty knife to1
put the center of the plastic rivets out (See Figure
3-30).
Remove both rivets.2
Use a phillips screw driver to extract the shoulder3
screws from the front frame (See Figure 3-31).
Use a T-20 Torx bit to extract the screws from the4
sides and back.
Remove the glass top.5
Control Board Removal
To remove the control board, first remove the glass top,
then (See Figure 3-32):
Use a needle nose pliers to compress top of control1
board support and lift control board off of control
board support.
Proceed to next control board support until control 2
board is removed from all control board supports.
Disconnect comm cable from control board.3
Remove control board.4
Figure 3-30. Plastic Rivets

Related product manuals