Component Removal
Induction Range (IR) Series
Induction Range (IR) Series
3-15
#827176 - Revision A.1 - December, 2016
Fan Assembly Removal
To remove the fan assembly, first remove the generator
plate, then (See Figure 3-36)
1 Press connector tab in and disconnect fan assembly
connector.
2 Use a small flat blade screw driver to spread the fan
assembly retainer tabs slightly to release fan assem-
bly.
3 Remove the fan assembly.
Generator Assembly Removal - IR304
To remove the generator assembly, first remove the
generator plate, then (See Figure 3-37):
Turn generator over and use T-20 or large flat blade1
screw driver to disconnect power wire harness.
Disconnect comm cable.2
Remove generator assembly.3
Generator Assembly Removal - IR365
To remove the generator assembly, first remove the
generator plate, then (See Figure 3-38):
Use a T-15 to remove wire clamp from generator1
being replaced.
Disconnect connecting wire spade terminals from2
the generator being replaced.
Disconnect the connecting ribbon cable from the3
generator being replaced.
Disconnect comm cable from the generator being4
replaced.
On four coil generator, turn generator over and use5
a T-20 or a large flat blade screw driver to discon-
nect power wire harness.
Remove generator.6
Figure 3-37. IR304 Generator Assembly
Figure 3-38. IR365 Generator Assembly
Figure 3-36. Fan Assembly Removal