4
3062881_0910
Installation information /
Maintenance information
Care Cleanthecasingwithadampclothandmilddetergent.
Thecomponentsinsidethegascondensingboilermayonlybecleaned
byaheatingcontractor.
Corrosion protection Never use or store sprays, solvents, chlorinated cleaning agents,
paints, adhesives, etc. in the vicinity of the gas condensing boiler.
Underunfavourableconditions,thesematerialsmayleadtocorrosion
inthegascondensingboilerandtheuesystem.Ductedventsrouted
througha roofmay alsocontain corrosive vapours. For that reason,
maintainasufcientlylargedistancetotheair/uegasterminal(minimum
recommendation:5m).
NB - only the heating contractor offers the required
knowledge and expertise!
- Theuserisresponsibleforarrangingaregularserviceofthesystem,
inordertoensurethereliableandsafefunctionofthegascondensing
boiler.
- Yourgascondensingboilershouldbeservicedannually.
- Maintenanceisexplicitlydetailedintheinstallationinstructions.
- Isolatetheappliancefromthepowersupplybeforeanymaintenance
work.
- Afteraserviceandbeforethegascondensingboilerisreturnedinto
use,checkthatallcomponentsthatwereremovedformaintenance
havebeenrettedcorrectly.
- Werecommendyouarrangeamaintenancecontractwithanapproved
heatingcontractor.
Service
Positioning / modications - Your gas condensing boiler should only be installed and modied
byanapprovedheatingcontractor,asonlytheyhavetheessential
knowledgetocarryoutsuchwork.
- Nevermodifyuegascomponents.
- Never close or restrict the ventilation apertures in doors or walls
when operating the boiler in open ue mode; only start the boiler
when the ue has been fully installed.
- For operation in balanced ue mode, only take the appliance into
use if the balanced ue system has been fully installed and the
wind protector is not covered up.
- Thegascondensingboilermayonlybeinstalledinroomsthatare
protectedfromfrost.
- Never isolate the appliance from the power supply when outside
temperaturesfallbelowzero,otherwisethereisariskofthesystem
freezingup.
- Nevermodifythedrainorthesafetyvalve.
Caution - failure to observe this rule may lead to a risk of re
as well as a risk of destruction, poisoning or explosion!
Do not use or store explosive and/or ammable materials, e.g.
petrol, thinners, paints, paper etc. inside the boiler room!