Contractor level parameters
The operating mode can only be displayed via WOLF control accessories with
eBUS capability. For procedures, check the operating instructions of the relevant
accessories.
Operating mode
(displayontheBM
programmingmodule)
Status HG Explanation Notes
0
Standby
1
Emissiontestmode
max.15min.
3
Heatdemand(heatingmode)
5
Heatdemandwithcycleblock
6
Cycleblock
seeHG09
7
Frostprotection-heating
seeA09
8
Softstart
seeHG26
15
Cylindermode
forboilers
16
Frostprotection-cylinder
< + 5 K
17
Pumprun-on-cylinder
seeHG19
20
Parallelcylindermode
seeA10
21
Max.cylinderheatingtimeexceeded
seeHG20,MI09
22
Sensoroperatingmode2,contactclosed
seeHG24
23
Sensoroperatingmode3,contactclosed
seeHG24