3061916_0611 Subjecttomodications 6.6701.615
GB
Installation and
operating instructions
Programming module BM-Solar
Wolf GmbH · Postfach 1380 · D-84048 Mainburg · Tel. +49-8751/74-0 · Fax +49-8751/741600 · Internet: www.wolf-heiztechnik.de

Questions and Answers

  • S
    Sophia HernandezAug 1, 2025
    What to do if my Wolf BM-Solar displays 'EEPROM fault'?
    • R
      Rita GarrettAug 1, 2025
      If your Wolf Control Unit displays an 'EEPROM fault', it indicates that parameter values are outside the valid range. To resolve this, reset the unit to its standard values by briefly interrupting the power supply, then check the values.
  • B
    Brian MatthewsAug 5, 2025
    What does it mean if the Wolf BM-Solar shows 'DCF signal or reception interference'?
    • H
      hillraymondAug 6, 2025
      If your Wolf Control Unit shows 'DCF signal or reception interference', it means there is no BUS connection or no DCF reception. Check the eBUS connection and DCF reception to resolve this issue.
  • J
    James HerreraAug 9, 2025
    What should I do if my Wolf BM-Solar displays 'SM1: Terminal SFK, solar sensor Collector faulty'?
    • E
      Erin RomeroAug 9, 2025
      If the Wolf Control Unit displays 'SM1: Terminal SFK, solar sensor Collector faulty', it indicates a faulty sensor or lead. Check the sensor and lead, and replace them if required.
  • R
    russell36Aug 13, 2025
    What should I do if my Wolf BM-Solar displays 'SM2: Terminal RLF, return sensor faulty'?
    • J
      jennifermorrisAug 13, 2025
      If the Wolf Control Unit displays 'SM2: Terminal RLF, return sensor faulty', it indicates a faulty sensor or lead. Check the sensor and lead, and replace them if required.
  • T
    tabitha93Aug 18, 2025
    What should I do if my Wolf BM-Solar Control Unit displays 'SM2: Terminal E3, sensor on input E3 faulty'?
    • B
      Barbara JonesAug 18, 2025
      If the Wolf Control Unit displays 'SM2: Terminal E3, sensor on input E3 faulty', it indicates a faulty sensor or lead. Check the sensor and lead, and replace them if required.
  • Z
    Zachary BennettAug 22, 2025
    What should I do if my Wolf BM-Solar displays 'SM1: Terminal SFS, solar sensor Cylinder faulty'?
    • N
      nandradeAug 22, 2025
      If the Wolf Control Unit displays 'SM1: Terminal SFS, solar sensor Cylinder faulty', it indicates a faulty sensor or lead. Check the sensor and lead, and replace them if required.
  • L
    Laura DillonAug 27, 2025
    What to do if the Wolf BM-Solar Control Unit pulse generator is faulty?
    • C
      Cody CarterAug 27, 2025
      If the pulse generator of your Wolf Control Unit is faulty, it means that either the pulse generator or its cable is defective. Check the pulse generator and the cable, and replace them if necessary.

Summary

Safety Instructions and Standards

Safety Instructions

Instructions for personal safety and operational reliability, using specific symbols and warnings.

Standards and Directives

Compliance with EC Directives (Low Voltage, EMC) and EN Standards for emissions and jamming.

Standards and Regulations

Installation and Commissioning

Requirements for qualified electricians and adherence to local power supply and VDE regulations for installation.

Warnings

Critical warnings against tampering with safety equipment and operating the system in an unsafe condition.

Maintenance and Repair

Guidelines for regular checks, qualified personnel for repairs, and using original spare parts.

Disposal and Recycling

Procedures for proper disposal of components and electronic scrap according to environmental standards.

Installation Guide - Module and Remote Control

Module Installation

Integrating the BM-Solar module into the SM solar module.

Remote Control Setup

Using the BM-Solar as a remote control via a wall mounting base.

Wall Mounting Base Installation

Securing the wall mounting base to a flush-mounting box or wall.

Installation Details - Wiring and Electrical

Electrical Connection

Requirements for qualified electricians for electrical connection and routing of sensor leads.

Remote Control Wiring

Wiring the wall mounting base with a two-core cable for remote control operation.

System Overview - Display Functions

Standard Display

Displays solar cylinder and collector temperatures on the top and bottom lines.

Status Display

Shows status of solar circuit pump and outputs A1-A3, and indicates BUS connection status.

Display Level - Information Access

Information Display (Info Key)

Pressing the Info key to scan additional display values like solar cylinder temperature (A01).

Display Values - SM1 and SM2 Modules

Display Values SM1 Solar Module

Lists display codes and designations for SM1 solar module, including temperatures, flow rates, and yields.

Display Values SM2 Solar Module

Lists display codes and designations for SM2 solar module, including cylinder/collector temps, flow rates, and status.

Display Values - Descriptions (A:01-A:06)

Display Value Descriptions A:01-A:06

Explains actual/max DHW temps, collector temps, return temp, and flow rate for SM1/SM2.

Display Values - Descriptions (A:07-A:12)

Display Values A:07-A:09

Describes inputs E3, max DHW temp (cylinder 2), and max collector temp (array 2).

Display Values A:10-A:12

Explains solar circuit pump run times and current output for SM1/SM2 modules.

Display Values - Descriptions (A:13-A:18)

Display Values A:13-A:16

Details current day yield and total yield (Wh, kWh, MWh) for the solar thermal system.

Display Values A:17-A:18

Explains solar heating status for cylinder 1 and cylinder 2, including successful completion criteria.

Display Values - Descriptions (A:19-A:21)

Display Values A:19-A:21

Explains max DHW temp (cylinder 3), solar circuit pump 3 run times, and solar heating status for cylinder 3.

Parameter Level - Access and Navigation

Access to Parameter Level

Activating the parameter level by pressing the rotary selector to view/change modifiable values.

Parameter Settings - SM1 Solar Module

Parameters for SM1 Solar Module

Details parameters like differential settings, temperatures, glycol selection, and BUS feed for SM1.

Parameter Settings - SM2 Solar Module (Part 1)

Parameters for SM2 Solar Module (Cylinders 1-2)

Details parameters for SM2 including cylinder differential, temperatures, bypass, and thermostat functions.

Parameter Settings - SM2 Solar Module (Part 2)

Parameters for SM2 Solar Module (Cylinders 3+)

Covers SM2 parameters for cylinder 3, operating modes, idle time, pump rates, and relay test.

System ON;OFF Operation

System ON;OFF Operation

Instructions for using the ON/OFF pushbutton, requiring a 3-second hold for shutdown.

Technical Specifications

Technical Specifications

Details supply voltage, power consumption, protection ratings (IP30), and ambient/storage temperatures.

Troubleshooting and Fault Codes

Fault Codes and Remedies

Lists fault codes (FC62-FC81), causes like sensor errors or BUS issues, and recommended checks or resets.

Wolf BM-Solar Specifications

General IconGeneral
ApplicationSolar thermal systems
ManufacturerWolf
Maximum input current20A
Output voltage12V/24V
Maximum output current20A