3061916_0611 13
A : 1 9
SM1: Notinstalled
SM2: The maximum DHW temperature of cylinder 3 over the
courseof24hoursisdisplayed.
Thisvalueisresetevery24hours.
SM1: Notinstalled
SM2: MaximumDHW
temperature
Solarcylinder3
SM1: Notinstalled
SM2: Theoverallhoursrunbysolarcircuitpump3aredisplayed.
Thisvaluecorrespondstothedisplay value x 10.
Thisvaluecanberesetto0bypressingandholdingdown
therotaryselectorforatleast10seconds.
A : 20
SM1: Notinstalled
SM2: Hoursrun
Solarcircuitpump3
A : 21
SM1: Notinstalled
SM2: Thisindicateswhethersolarheatingofcylinder3hasbeen
completedsuccessfullywithinthelast24hours.
This applies if, within 24 hours prior to 14:00 h, the set
DHWtemperatureselectedattheheatingappliancewasexceeded
bysolarheating.
Inthiscase,thesetDHWtemperatureattheheatingappliance
willbesettotheminimumcylindertemperature(cylinderreheating
blocked).
Thisfunctionisonlyavailableifthesolarmoduleisoperatedas
partofaWolfcontrolsystem(forafunctiondescription,seethe
SMsolarmodulemanual).
SM1: Notinstalled
SM2: Solarheatingstatus
Cylinder3
Display level