3061916_0611 11
SM1: Notinstalled
SM2: The maximum DHW temperature of cylinder 2 over the
courseof24hoursisdisplayed.
Thisvalueisresetevery24hours.
A : 0 8
SM1: Notinstalled
SM2: MaximumDHW
temperature
Solarcylinder2
SM1: Notinstalled
SM2: The maximum collector temperature of collector array 2
overthecourseof24hoursisdisplayed.
Thisvalueisresetevery24hours.
A : 0 9
SM1: Notinstalled
SM2: Maximumcollector
temperature
Collectorarray2
SM1: Theoverallhoursrunbythesolarcircuitpumparedisplayed.
SM2: Theoverallhoursrunbysolarcircuitpump1aredisplayed.
Thisvaluecorrespondstothedisplay value x 10.
Thisvaluecanberesetto0bypressingandholdingdown
therotaryselectorforatleast10seconds.
A : 1 0
SM1: Hoursrun
Solarcircuitpump
SM2: Hoursrun
Solarcircuitpump1
SM1: Notinstalled
SM2: Theoverallhoursrunbysolarcircuitpump2aredisplayed.
Thisvaluecorrespondstothedisplay value x 10.
Thisvaluecanberesetto0bypressingandholdingdown
therotaryselectorforatleast10seconds.
A : 1 1
SM1: Notinstalled
SM2: Hoursrun
Solarcircuitpump2
SM1/ Thecurrentoutputofthesolarcircuitisdisplayed.
SM2:Thisvalueisonlyavailableifareturnsensororaheatmeter
sethasbeenconnectedtotheassociatedSMsolarmodule,
andvalue1or2hasbeenselectedforparameter08.
A : 1 2
Currentoutput
SM1: Notinstalled
SM2: The current value captured by the sensor connected
to input E3 is displayed. Subject to the conguration
set at the SM2, this may be the buffer temperature, the
actualDHWtemperatureofsolarcylinder2,thecollector
temperatureofcollectorarray2orthebypasstemperature.
Thisvaluewillonlybedisplayedifatemperaturesensor
hasbeenconnected.
A : 0 7
SM1: Notinstalled
SM2: InputE3
Display level