3061916_0611 17
SOL 29 * p 29 *
Startdifferentialsolarcylinder3 5K 30K 8K
SOL 30 * P 30 *
Stopdifferentialsolarcylinder3 2K 20K 4K
SOL 31 * P 31 *
Maximumtemperature,solar
cylinder3
15°C 90°C 60°C
SOL 32 * P 32 *
Assignment,solarcylinder3 0 8 8
SOL 33 * P 33 *
Hysteresis,solarcylinder1 0.5K 5K 1K
SOL 34 * P 34 *
Hysteresis,solarcylinder2 0.5K 5K 1K
SOL 35 * P 35 *
Hysteresis,solarcylinder3 0.5K 5K 1K
SOL 36 * P 36 *
Solarcylinderemergencyshutdown1
60°C 95°C 95°C
SOL 37 * P 37 *
Solarcylinderemergencyshutdown2
60°C 95°C 95°C
SOL 38 * P 38 *
Solarcylinderemergencyshutdown3
60°C 95°C 95°C
SOL 39 * P 39 *
Minimumcollectorlimit -25°C 90°C 10°C
SOL 40 * P 40 *
Minimumbufferlimit 10°C 90°C 10°C
SOL 41 * P 41 *
Functioncheck,owrate 0(OFF) 1(ON) 0
SOL 42 * P 42 *
Functioncheck
Gravitybrake
0(OFF) 60°C 40°C
SOL 43 * P 43 *
Lowerpumprate 28 % 100 % 30 %
SOL 44 * P 44 *
Reversecoolingfunction 0(OFF) 1(ON) 0
SOL 45 * P 45 *
Selectioncylinderthermostat
function
1 3 1
SOL 46 * P 46 *
Prioritysolarcylinder2 0 2 1
SOL 47 * P 47 *
Cylinderoperatingmode 1 3 2
SOL 48 * P 48 *
Cyclicalheatingtime 0min. 60min. 30min.
SOL 49 * P 49 *
Idletime 0min. 60min. 5min.
SOL 50 * P 50 *
Blockingtime,solarcircuit pump
orelectricalvalve
0s 300s 90s
SOL 51 * P 51 *
Proportionofglycolinwater
P 10=0→P 51 Notadjustable
P 10 =1:TyfocorL(Anro)
P 10 =2→P 51 Notadjustable
P 10 =3→P 51 Notadjustable
P 10 =4→Ethyleneglycol
----
20 %
----
----
20 %
----
75%
----
----
80 %
----
45%
----
----
45%
SOL 52 * P 52 *
Cylinder switching with external
cylinderheating
0 1 0
SOL 53 * P 53 *
Samplinginterval 1s 60s 10s
SOL 54 * P 54 *
Internalpumpspeed 5% 20 % 5%
SOL 55 * P 55 *
Upperpumprate 50% 100 % 100 %
SOL 6O p 60
Relaytest 1 5 1
Parameter
BM
Parameter
BM-Solar
Explanation
Setting range Factory
setting
min. max.
For function descriptions of the individual parameters, see the SM solar module instruction
manual.
*ParametersonlyeffectivefromsoftwareversionSM1/SM2228_04.
Parameter level