Page #4 background imageLoading...
Page #4 background image
GB
Operating Instructions
03
DS12F DS15F DS28F DS36F ED50F ED50Feco
Max. working area 90 m
3
100 m
3
140 m
3
190 m
3
230 m
3
330 m
3
Air flow step 1 256 m
3
/hour 256 m
3
/hour 190 m
3
/hour 197 m
3
/hour 129 m³/hour 172 m
3
/hour
Air flow step 2 - 520 m
3
/hour 336 m
3
/hour 336 m
3
/hour 296 m
3
/hour 400 m
3
/hour
Dehumidifying at 27˚C and 60% r.h. 6.1 l/day 6.7 l/day 10.4 l/day 13.2 l/day 21,1 l/day 25,2 l/day
Dehumidifying at 30˚C and 80% r.h. 11.1 l/day 12.0 l/day 17.5 l/day 20.8 l/day 33,2 l/day 40 l/day
Power at 27˚C and 60% r.h. 220W/hour 240 W/hour 460 W/hour 510 W/hour 850 W/hour 790 W/hour
Tank volume 10.4 litres 10.4 litres 10.4 litres 10.4 litres 10.4 litres 10.4 litres
Cooling medium, freon-free R134A R134A R134A R134A R410A R410A
Dimensions in mm., L x B x H 343 x 406 x 527 343 x 406 x 527 343 x 406 x 527 343 x 406 x 527 343 x 406 x 527 343 x 406 x 527
Weight 22 kg. 22 kg. 24 kg. 26 kg. 28 kg. 28 kg.
Noise level in decibels 38 dB 38-58 dB 38-58 dB 38-58 dB 38-58 dB 38-58 dB
TECHNICAL DATA
PROBLEM SOLUTION
Dehumidifier does not start - Check that dehumidifier is connected to electricity and that fuse has not gone
- If the warning light is on, check that the water reservoir is empty and correctly placed in the dehumidifier.
Check that float is free
- Check that hygrostat is working. Dehumidifier should start when hygrostat is in Maximum position
Does not dehumidify - Check that fan is spinning
- Check that air can flow freely through the dehumidifier. Front grid and air filter should be clean and dehumidifier should stand
20-30cm from wall
- Listen for sound of compression, but bear in mind that the dehumidifier may be in a dehumidifying cycle, when the compression stops. Wait initially for about 35
minutes.
- Check that a thick coating of ice has not formed on the cooling coils.
High noise level - Increase distance between dehumidifier and surrounding surfaces
- Cooling coils may be in contact with one another and cause vibration. Disconnect dehumidifier from electricity and separate coils
Ice formation on cooling coils - Remove air filter at rear of dehumidifier and check that no dust or fluff is obstructing passage of air through machine
- Timer which controls defrosting may be broken, in which case compression will not stop regularly
No water enters reservoir - Check for obstruction to drip-tray above water reservoir
Does not turn off when water
reservoir is full
- It is important that the float moves freely in the water reservoir. If it does not, it will not respond to water levels and prevent dehumidifier from stopping
If none of the above works, you should contact your nearest retailer for checking and possible overhaul of dehumidifier