PROBLEM CAUSE SOLUTION
Dehumidier does not work The power is not connected - Check that dehumidier is connected to electricity and that fuse has not gone
- Check that the water reservoir is empty and correctly placed in the dehumidier.
Does not dehumidify -The water container is full.
-The water container has not
been replaced correctly.
-The air lter is clogged.
The temperature or relative
humidity in the room where
the device is operatingis too low.
- Remove the water from the container.
- Place the water container in the correct position.
- Clean the air lter.
- Check that air can ow freely through the dehumidier. Front grid and air lter should be clean and dehumidier should stand
20-30cm from wall
- Check that a thick coating of ice has not formed on the cooling coils.
The dehumidier works, but
reduces the relative huidity
insuciently.
-The room is too large.
-There are too many sources
of humidity.
-There is too much ventilation.
- We recommend using a dehumidier with a greater capacity.
- We recommende using a dehumidier with a greater capacity.
- Reduce ventilation (e.g close windows and shut doors.)
If none of the above works, you should contact your nearest retailer for checking and possible overhaul of dehumidier
MDK11 MDK13
Max. working area 50m
2
60m
2
Air flow 77m3/h 90m3/h
Dehumidifying at 30˚C and 80% r.h. 10 L/ 24 H 12 L/ 24 H
Power at 30˚C and 80% r.h. 210 W 200 W
Tank volume 1,8 liters 1,8 liters
Refrigerant R290 (55g) R290 (60g)
Voltage 230V 230V
Frequency 50Hz 50Hz
Current 0,95A 0,9A
IP Codet IP22 IP22
Dimensions in mm, LxWxH 290x190x478 290x190x478
TECHNICAL DATA
Control panel
Handle
Air plate
Tank
Filter
*Technical changes and improvements may occur. All values
are approximate and may vary due to external circumstances
such as temperature, ventilation and humidity.
Power cord